Document IIF

Conditionnement d'air mobile utilisant la chaleur récupérée.

Waste heat driven MAC.

Résumé

A prototype compact generator using the activated carbon - ammonia pair based on the plate heat exchanger concept has been designed and built at Warwick University. The novel generator has low thermal mass and good heat transfer. The heat exchanger uses nickel-brazed shims and spacers to create adsorbent layers only 4 mm thick between pairs of liquid flow channels of very low thermal mass. The prototype sorption generator manufactured was evaluated under EU car air conditioning test conditions. The prototype sorption generator is described and its experimental performance reported. While driven with waste heat from the engine coolant water (at 90°C), a pair of the current prototype generators (loaded with about 1 kg of activated carbon) operating out of phase has produced an average cooling power 1.6 kW with about 2 kW peaks. The typical average COP obtained is 0.22.

Documents disponibles

Format PDF

Pages : 2010-1

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Waste heat driven MAC.
  • Identifiant de la fiche : 2010-0575
  • Langues : Anglais
  • Source : 1st IIR International Conference on Sustainability and the Cold Chain
  • Date d'édition : 29/03/2010

Liens


Voir d'autres communications du même compte rendu (82)
Voir le compte rendu de la conférence