Contrebalancer la lumière diurne, les reflets et les difficultés de vision : le rôle d'une stratégie de système de régulation de l'ombrage externe.
Counterbalancing daylighting, glare and view out: the role of an external shading system control strategy.
Numéro : pap. 855
Auteurs : KONSTANTOGLOU M., KONTADAKIS A., TSANGRASSOULIS A.
Résumé
To protect building shells from solar radiation, allow daylight in and improve the envelope’s performance, it is critical to adopt shading systems with advanced controlled strategies. This research explores the definition of an optimized control strategy that counterbalances solar protection – daylight adequacy, glare reduction and view out. More specifically it examines a new dynamic control strategy for an exterior non-retractable louver system installed in a typical office space. Primary goal of the control system is to increase daylighting levels and maintain a predefined illuminance level on the work plane surface, while managing solar gains and protecting from glare. The proposed control strategy is defined with the optimization process of three different control strategies based on three performance criteria accordingly: required illuminance levels; glare reduction and; view out. To define the dynamic control strategy, a series of simulations were performed in EnergyPlus. Consumption for lighting, heating and cooling has been calculated for a set of slat angles of the shading system. Hourly daylighting simulations calculated illuminance levels on predefined sensor points. For each point and each hour of the day and year, tilt angle is estimated while illuminance is calculated using linear interpolation between adjacent tilt angle values. To optimize the control performance based in occupants’ visual comfort, an annual glare analysis was conducted using the daylight glare index concept (DGI).
Documents disponibles
Format PDF
Pages : 10 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Counterbalancing daylighting, glare and view out: the role of an external shading system control strategy.
- Identifiant de la fiche : 30010008
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Date d'édition : 16/06/2013
Liens
Voir d'autres communications du même compte rendu (424)
Voir le compte rendu de la conférence
Indexation
- Thèmes : Conditionnement d'air pour le confort
- Mots-clés : Bureau; Immeuble; Rayonnement solaire; Simulation; Ombrage; Contrôle
-
Comparative analysis of PV shading devices for ...
- Auteurs : HAASE M., KHEZRI N.
- Date : 16/06/2013
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
Voir la fiche
-
Assessment of long term visual and thermal comf...
- Auteurs : ATZERI A. M., CAPPELLETTI F., SHEN H., et al.
- Date : 14/07/2014
- Langues : Anglais
- Source : 2014 Purdue Conferences. 3rd International High Performance Buildings Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Integration of photovoltaics into building ener...
- Auteurs : STARKE M., NUTARO J., IRMINGER P., et al.
- Date : 14/07/2014
- Langues : Anglais
- Source : 2014 Purdue Conferences. 3rd International High Performance Buildings Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Thermal comfort in two European active houses: ...
- Auteurs : FOLDBJERG P., RASMUSSEN C., ASMUSSEN T.
- Date : 16/06/2013
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
Voir la fiche
-
MONTAGE D'UNE INSTALLATION DE CONDITIONNEMENT D...
- Auteurs : HISAKI H.
- Date : 1991
- Langues : Japonais
- Source : SHASE - vol. 65 - n. 7