Document IIF
Conversion expérimentale d’un congélateur ultra-basse température au R404/R23 en utilisant du R448A et des détendeurs électroniques.
Experimental retrofit of an R404A/R23 ultra-low temperature freezer using R448A and electronic expansion valves.
Auteurs : GIMÉNEZ-PRADES P., NAVARRO-ESBRÍ J., UDROIU C-M., MOTA BABILONI A.
Type d'article : Article de la RIF
Résumé
The lack of regulations that limit the GWP of refrigerants operating in vapour compression systems with a target temperature below –50°C has caused slower market development. Therefore, limited refrigerants and technologies for ultra-low temperature (ULT) refrigeration have been studied. In this work, an experimental assessment of R448A as a lower-GWP alternative to R404A in the high-temperature stage of a ULT two-stage cascade refrigeration system is done using R23 as the low-temperature stage refrigerant. Furthermore, capillary tubes and electronic expansion valves are compared as expansion devices. First, the pull-down performance starting from three room temperatures (15, 20, and 25°C) down to –80°C is analysed. Then, the hysteresis operation with those ambient temperatures and set freezer temperatures of –80, –70, –60, and –50°C is studied. The pull-down time was higher (38 to 55 min slower) using the capillary tubes compared to the electronic expansion valves. Also, the energy consumption of the hysteresis operation was higher (up to 32.3% higher) using the capillary tubes. The electronic expansion valves obtained comparable energy consumption and cooling capacity with R404A/R23 and R448A/R23. The highest COP is achieved by R448A/R23 (up to 10.2% higher than R404A/R23). Therefore, the suitability of R448A as a replacement for R404A in ULT refrigeration is confirmed.
Documents disponibles
Format PDF
Pages : 217-227
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Experimental retrofit of an R404A/R23 ultra-low temperature freezer using R448A and electronic expansion valves.
- Identifiant de la fiche : 30033555
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 171
- Date d'édition : 03/2025
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2025.01.017 Get rights and content
Liens
Voir d'autres articles du même numéro (20)
Voir la source
Indexation
- Thèmes : Cryogénie: applications de faible puissance, cryoréfrigérateurs
- Mots-clés : Conversion; R404A; R23; Congélateur; Basse température; R448a; Tube capillaire; Experimentation
-
Investigation of the solid-liquid phase equilib...
- Auteurs : BAE J., LEE C., JEONG S.
- Date : 23/04/2017
- Langues : Anglais
- Source : 5th IIR Conference on Thermophysical Properties and Transfer Processes of Refrigerants.
- Formats : PDF
Voir la fiche
-
Temperature instabilities in a long-running pul...
- Auteurs : WALDAUF A., THÜRK M., SEIDEL P.
- Date : 22/07/2002
- Langues : Anglais
- Source : Proceedings of the nineteenth International Cryogenic Engineering Conference. ICEC 19.
Voir la fiche
-
Experimental investigation of a novel cascade r...
- Auteurs : XU Y., MICKOLEIT E., THOMAS C., JAGER A., BREITKOPF C., HESSE U.
- Date : 11/2021
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 131
- Formats : PDF
Voir la fiche
-
Phase shifters in a high frequency pulse-tube c...
- Auteurs : MA J., HOU Y. K., LONG X. H., et al.
- Date : 22/04/2003
- Langues : Anglais
- Source : Cryogenics and refrigeration. Proceedings of ICCR 2003.
Voir la fiche
-
Development of the 0.5 W/80 K co-axial and U-sh...
- Auteurs : LIANG J., HUANG Z. W., ZHANG H., et al.
- Date : 22/07/2002
- Langues : Anglais
- Source : Proceedings of the nineteenth International Cryogenic Engineering Conference. ICEC 19.
Voir la fiche