Cryoconservation du sperme humain à l'aide de vitesses de refroidissement rapides.

Cryopreservation of human sperm using rapid cooling rates.

Auteurs : GRISCHENKO V. I., DUNAEVSKAYA A. V., BABENKO V. I.

Type d'article : Article

Résumé

The majority of protocols used for cryopreservation of human spermatazoa involve low cooling rates. However, calculations have shown that an optimal cooling rate is about 7 x 10 000 °C/min. The authors studied the effect of high cooling rates, variation of osmolarity of the cryoprotectant medium and the glycerol content. The results demonstrated that decreasing the cooling rate down to 1.75-2.5 x10 000 °C/min induced a statistically significant reduction in sperm motility. The cooling rate of 8-11 x 10 000 °C /min enabled only a small percentage of spermatozoa to retain their motility.

Détails

  • Titre original : Cryopreservation of human sperm using rapid cooling rates.
  • Identifiant de la fiche : 2004-0022
  • Langues : Anglais
  • Source : CryoLetters - vol. 24 - n. 2
  • Date d'édition : 03/2003
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.

Liens


Voir d'autres articles du même numéro (4)
Voir la source