Cryorefroidisseur à tube à pulsation de type Stirling de 1 kW à 77 K.
Stirling-type pulse tube cryocooler with 1 kW of refrigeration at 77 K.
Auteurs : POTRATZ S. A., ABBOTT T. D., JOHNSON M. C., et al.
Résumé
A large capacity Stirling-type pulse tube cryocooler has been successfully developed by Praxair, Inc. Performance testing of both the prototype and initial production models of the pulse tube cryocooler has verified a refrigeration capacity of 1 kW at 77 K using a 20 kW, dual-opposed pressure wave generator from CFIC, Inc. These results were obtained using nitrogen subcooling test methods. The cryocooler design incorporates sophisticated geometry to successfully minimize streaming and other loss mechanisms which have limited the performance of previous large pulse tube cryocooler designs. The intended application of this unit is for the commercial HTS (high-temperature superconductivity) market. The current design will be deployed for field testing in Columbus, OH where reliability and performance will be measured in an operating HTS application.
Détails
- Titre original : Stirling-type pulse tube cryocooler with 1 kW of refrigeration at 77 K.
- Identifiant de la fiche : 2008-1446
- Langues : Anglais
- Date d'édition : 16/07/2007
- Source : Source : Adv. cryog. Eng., Trans. CEC/AIP Conf. Proc./Proc. CEC, Chattanooga, Tennessee
vol. 53; CP985; 42-48; fig.; phot.; tabl.; 6 ref.
Indexation
-
A single-stage pulse tube cooler working at 11 K.
- Auteurs : HE Y. L., QIU L. M., GAN Z. H., et al.
- Date : 17/07/2006
- Langues : Anglais
- Source : Multiconference CryoPrague 2006 (9th Cryogenics 2006, ICEC 21, ICMC'06)
- Formats : PDF
Voir la fiche
-
Development of the 0.5 W/80 K co-axial and U-sh...
- Auteurs : LIANG J., HUANG Z. W., ZHANG H., et al.
- Date : 22/07/2002
- Langues : Anglais
- Source : Proceedings of the nineteenth International Cryogenic Engineering Conference. ICEC 19.
Voir la fiche
-
DC flow in a high frequency miniature pulse-tub...
- Auteurs : HOU Y. K., JU Y. L., ZHOU Y., et al.
- Date : 22/07/2002
- Langues : Anglais
- Source : Proceedings of the nineteenth International Cryogenic Engineering Conference. ICEC 19.
Voir la fiche
-
A novel three-stage 4 K pulse tube cryocooler.
- Auteurs : WANG C.
- Date : 14/06/2006
- Langues : Anglais
Voir la fiche
-
Refrigeration performance study on pulse tube r...
- Auteurs : CHEN G. B., TANG K., JIN T., et al.
- Date : 22/07/2002
- Langues : Anglais
- Source : Proceedings of the nineteenth International Cryogenic Engineering Conference. ICEC 19.
Voir la fiche