Document IIF
Design for operation-indoor air temperature and humidity with fan-coil system.
Auteurs : NIU J. L., CHAN D. W. T., BURNETT J.
Résumé
Fan coils units(FCU) system is the most commonly used air-conditioning system for large commercial buildings. The paper reviews the common methods used by design engineers for FCU system parameter specifications, currently covered in ASHRAE HVAC guide and China MOC HVAC guide. It is identified that oversizing the fan coil units can cause relative humidity excesses, especially with chilled water flow control methods. These analysis are supported by some real life survey results on the thermal performances of fan-coil systems in Hong Kong, and by a preliminary simulation results. The most prominent finding of the on site survey is that most of the office spaces served by FCU systems are severely overcooled, and that large variation and high relative humidity occur in FCU served rooms. The paper also emphasizes the importance of optimizing the system parameters and FCU cooling capacity control methods for a more hygienic humidity control and avoiding overcooling .
Documents disponibles
Format PDF
Pages : p 90-95
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Design for operation-indoor air temperature and humidity with fan-coil system.
- Identifiant de la fiche : 30033756
- Langues : Anglais
- Sujet : Technologie
- Source : International Symposium on Air Conditioning in High Rise Buildings - 1997
- Date d'édition : 09/1997
- Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.
Liens
Voir d'autres communications du même compte rendu (109)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
Conditionnement d'air pour le confort;
Equipements d'humidification/déshumidification - Mots-clés : Conditionnement d'air; Température; Humidité relative; Refroidissement; Contrôle; Performance; Optimisation
- Tags : A traduire
-
Performance Test of Dense Membrane for Vaccum M...
- Auteurs : LEE J., KU D., CHOI S., JEONG S., BAE S., KIM M.
- Date : 31/08/2021
- Langues : Anglais
- Source : 13th IEA Heat Pump Conference 2021: Heat Pumps – Mission for the Green World. Conference proceedings [full papers]
- Formats : PDF
Voir la fiche
-
Comparison on Vacuum Membrane Dehumidification ...
- Auteurs : LIM H., LEE J., CHOI S., KIM S., JUNG M., LIM J., KIM M.
- Date : 31/08/2021
- Langues : Anglais
- Source : 13th IEA Heat Pump Conference 2021: Heat Pumps – Mission for the Green World. Conference proceedings [full papers]
- Formats : PDF
Voir la fiche
-
Air conditioning by the combination of radiant ...
- Auteurs : BUSWEILER U.
- Date : 01/11/1993
- Langues : Anglais
Voir la fiche
-
Modelling and experimental study on a direct ex...
- Auteurs : CHEN W., CHAN M. Y., WENG W., et al.
- Date : 09/07/2018
- Langues : Anglais
- Source : 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Analysis on hydrophobic membrane-based air pre-...
- Auteurs : WANG Z., HU J., LI R., et al.
- Date : 09/07/2018
- Langues : Anglais
- Source : 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche