Résumé
Linear compressors can be used for refrigeration systems due to higher efficiency, oil-free operation and compactness. One major challenge for linear compressor is the sensing of piston position. This paper presented a novel method to detect the piston position at resonance without a piston position sensor. Inductive coil was wounded around the middle core and the end core. The peak-to-peak flux linkage at two zero crossing points of measured current was calculated for various strokes for resonance operation. The results show that both the peak-to-peak flux linkage of end core and middle core vary linearly with the stroke. A linear function was fitted for peak-to-peak flux linkage at various strokes. The maximum error between calculated peak-to-peak flux linkage with measured current and linear fitting result is about 6%. When linear compressor is operated off resonance, the flux linkage difference is smaller than that at resonance. It can be concluded that inductive coil can be used to detect the compressor stroke thus to modulate the cooling capacity of the refrigeration system.
Documents disponibles
Format PDF
Pages : 6
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Sensor-less position detection of oil-free linear compressor for refrigeration.
- Identifiant de la fiche : 30026404
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Date d'édition : 24/08/2019
- DOI : http://dx.doi.org/10.18462/iir.icr.2019.0313
Liens
Voir d'autres communications du même compte rendu (632)
Voir le compte rendu de la conférence
Indexation
- Thèmes : Compresseurs
- Mots-clés : Compresseur linéaire; Résonance; Puissance frigorifique; Serpentin; Piston; Flux; Experimentation; Compresseur sec
-
Study on the output pressure amplitudes of the ...
- Auteurs : ZHI X., CAO R., JIANG X., et al.
- Date : 11/2019
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 107
- Formats : PDF
Voir la fiche
-
A novel linear electromagnetic-drive oil-free r...
- Auteurs : LIANG K., STONE R., DADD M., et al.
- Date : 04/2014
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 40
- Formats : PDF
Voir la fiche
-
Modeling and measurement of a moving coil oil-f...
- Auteurs : JOMDE A., ANDERSON A., BHOJWANI V. K., et al.
- Date : 04/2018
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 88
- Formats : PDF
Voir la fiche
-
Dynamic behavior analysis of a moving coil oil-...
- Auteurs : LI C., ZOU H., CAI J., JIANG Y., GUO C.
- Date : 01/2022
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 133
- Formats : PDF
Voir la fiche
-
Effects of the driving voltage waveform on the ...
- Auteurs : LI C., LI J., TANG L., et al.
- Date : 12/2019
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 108
- Formats : PDF
Voir la fiche