Résumé
According to a common practice in the Czech republic, the majority of industrial halls without specific technology-related temperature demands were ventilated only with outdoor air during the summer period. At newly constructed halls, with specific requirements for thermal comfort of employees and with technology-related requirements for the air temperature, utilization of air conditioning is necessary. A correct design of an air conditioning device requires knowledge of real cooling loads during the building operation, determination of their value should be as accurate as possible. At industrial halls with a large nominal power input of installed equipment, the internal cooling load is often a major part of the overall space cooling load. A calculation procedure of cooling load from internal heat sources is explained using examples. Three typical industrial halls were chosen as case studies: a hall with a small number of large heat sources, then a hall with machinery with a specified temperature demand and finally a hall with a large number of small heat sources.
Détails
- Titre original : Stanovení vnitrní tepelné záteze prumyslových hal.
- Identifiant de la fiche : 2009-1294
- Langues : Tchèque
- Source : Vytápení Vetrání Instalace - vol. 18 - n. 2
- Date d'édition : 2009
Liens
Voir d'autres articles du même numéro (2)
Voir la source
-
Remplacement du système de conditionnement d'ai...
- Auteurs : LIANG J., WEI Y., WANG J.
- Date : 10/2000
- Langues : Chinois
- Source : HV & AC - vol. 30 - n. 136
Voir la fiche
-
Design of an evaporative cooling ventilation sy...
- Auteurs : PRASAD M.
- Date : 17/08/2003
- Langues : Anglais
- Source : 21st IIR International Congress of Refrigeration: Serving the Needs of Mankind.
- Formats : PDF
Voir la fiche
-
Détermination de la charge thermique d'une sall...
- Auteurs : NOVY R., SIMACEK P.
- Date : 1996
- Langues : Tchèque
- Source : Vytápení Vetrání Instalace - vol. 5 - n. 3
Voir la fiche
-
We're on deadline: printing press heat gain is ...
- Auteurs : WESSEL D. J.
- Date : 2004
- Langues : Anglais
- Source : ASHRAE Transactions. 2004 Annual Meeting, Nashville, Tennessee, USA. Volume 110, part 2 + CD-ROM.
Voir la fiche
-
Integrated heating-cooling energy systems in in...
- Auteurs : MRÓZ T. M.
- Date : 15/10/2008
- Langues : Anglais
- Source : Projektowanie i eksploatacja przyjaznych srodowisku systemów chlodniczych i klimatyzacyjnych. Miedzynarodowa konferencja. XL Dni chlodnictwa.
- Formats : PDF