Recommandé par l'IIF / Document IIF

Détermination du transport thermique à travers les parois/cloisons des appareils de froid domestique.

Determining the heat flow through the cabinet walls of household refrigerating appliances.

Résumé

The increase of the thermal conductivity of PUR foam in the insulation of the cabinet is an important cause for aging processes of household refrigerating appliances. To determine the influence of the PUR foam aging on energy consumption, the development of a new measurement method is necessary because current methods influence the aging behavior of household refrigerators and are therefore not applicable in general. Based on a latent heat sink, constructed as an ice water bucket, a new measurement method is developed to determine the k · A value over time. With this method, the k · A value of four household refrigerating appliances was determined over an interval of 14 months. The k · A value increased between 3.6% and 11.5% during this period.

Documents disponibles

Format PDF

Pages : 235-242

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Determining the heat flow through the cabinet walls of household refrigerating appliances.
  • Identifiant de la fiche : 30028030
  • Langues : Anglais
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 121
  • Date d'édition : 01/2021
  • DOI : http://dx.doi.org/10.1016/j.ijrefrig.2020.10.007

Liens


Voir d'autres articles du même numéro (31)
Voir la source