Document IIF

Détermination expérimentale de la capacité de décompression du prototype de limiteur de pression (PRD) pour les enveloppes sous vide des équipements cryogéniques.

Experimental determination of the relieving capacity of the pressure relief device (PRD) prototype for vacuum jackets of cryogenic equipment.

Numéro : 128

Auteurs : POLINSKI J., SLAWINSKI P.

Résumé

Recently, Wroclaw University of Science and Technology (WUST) in Poland has developed a pressure relief device (PRD) prototype for vacuum jackets to be used in cryogenic devices and systems, which are under the design and to be delivered by WUST for a number of superconductivity-based accelerator projects. The PRD prototype is of the re-closing design type and comprise the O-ring sealed flap that seals to the seat by the spring. The paper presents the detailed design of the PRD prototype, description of the test stand for PRD reliving capacity determination and exemplary measurement results of the PRD prototype for different compressions of the sealing spring. Based on the proposed theoretical background and obtained experimental data, the procedure for the sprig-loaded PRD sizing is provided.

Documents disponibles

Format PDF

Pages : 7 p.

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Experimental determination of the relieving capacity of the pressure relief device (PRD) prototype for vacuum jackets of cryogenic equipment.
  • Identifiant de la fiche : 30031053
  • Langues : Anglais
  • Source : Proceedings of the 17th IIR International Conference on Cryogenics, Dresden, Germany, april 25-28 2023
  • Date d'édition : 25/04/2023
  • DOI : http://dx.doi.org/10.18462/iir.cryo.2023.0128

Liens


Voir d'autres communications du même compte rendu (33)
Voir le compte rendu de la conférence