Développement d'un compresseur à oscillation au rendement très élevé pour un fonctionnement au frigorigène R32.

Development of high efficiency swing compressor for R32 refrigerant.

Numéro : pap. 1286

Auteurs : YAMAMOTO Y., KANAYAMA T., YUASA K., et al.

Résumé

In the age of global warming, energy saving features and overall reduction of environmental impact are critical components that must be addressed when developing new HVAC units. We chose R32 refrigerant, with its lower LCCP (Life Cycle Climate Performance) as a more sustainable choice than R410A (Taira, 2010). However, R32 has its drawbacks. Due to its smaller molecular weight, internal leakage loss is higher for R32. Moreover, high discharge gas temperature decrease the reliability of the compressor, and make a large overheating loss increase. In this study, we will describe the technologies that were developed to overcome these drawbacks. We will also present the performance and reliability of the newly developed high efficiency swing compressor series for R32 refrigerant.

Documents disponibles

Format PDF

Pages : 7 p.

Disponible

  • Prix public

    20 €

  • Prix membre*

    15 €

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Development of high efficiency swing compressor for R32 refrigerant.
  • Identifiant de la fiche : 30014127
  • Langues : Anglais
  • Source : 2014 Purdue Conferences. 22nd International Compressor Engineering Conference at Purdue.
  • Date d'édition : 14/07/2014

Liens


Voir d'autres communications du même compte rendu (138)
Voir le compte rendu de la conférence