Développement d'un détendeur à écoulement diphasique pour les pompes à chaleur au CO2 et les conditionneurs d'air.

Development of two-phase flow expander for CO2 heat pumps and air conditioners.

Auteurs : SAKITANI K., MORIWAKI M., OKAMOTO M., et al.

Résumé

The authors developed a two-phase flow expander for CO2 heat pumps and air-conditioners to improve the performance of a transcritical cycle. They selected the swing type as an evaluation result of the existing pump and compressor types from the viewpoints of performance, reliability with two-phase flow, applicable volume, and productivity when applied to expanders. The test results of the newly designed prototype of a two-stage swing expander showed high efficiency in energy recovery. According to the evaluation made by calculation when mounted on a heat pump, the expander gives substantial reduction in heating energy consumption when compared with traditional combustion type heaters.

Détails

  • Titre original : Development of two-phase flow expander for CO2 heat pumps and air conditioners.
  • Identifiant de la fiche : 2006-2818
  • Langues : Anglais
  • Source : 8th IEA Heat Pump Conference 2005: global advances in heat pump technology, applications, and markets. Conference proceedings [CD-ROM].
  • Date d'édition : 02/05/2005

Liens


Voir d'autres communications du même compte rendu (57)
Voir le compte rendu de la conférence