Développement d'un système de chauffage d'eau à pompe à chaleur avec un compresseur hermétique rotatif "swing" à dioxyde de carbone.

[In Japanese. / En japonais.]

Auteurs : UCHIDA M., KURODA M.

Type d'article : Article

Résumé

A heat pump water heater system using carbon dioxide as a refrigerant can supply high-temperature water efficiently. Carbon dioxide is a natural working fluid without flammability, toxicity or an environmental impact. On the other hand, carbon dioxide is a refrigerant which has a high operating pressure and density. The authors chose a swing rotary compressor as the solution. Noise is an important issue in a system operating at at night-time. The authors developed a new compact heat exchanger and a new fan for suitable operation. As a result, they developed a new heat pump water heater system with 4.02 COP and a 38 dB operating noise level.

Détails

  • Titre original : [In Japanese. / En japonais.]
  • Identifiant de la fiche : 2005-0121
  • Langues : Japonais
  • Source : Refrigeration - vol. 79 - n. 917
  • Date d'édition : 2004

Liens


Voir d'autres articles du même numéro (6)
Voir la source