Résumé
Supermarkets are commercial buildings with major energy consumption and contribute also to relatively large direct emissions of greenhouse (GHG) through emissions of refrigerants from the refrigeration plants and the air conditioning system installed. The huge majority of these systems, which are installed in European supermarkets, are applying HFC-404A as working fluid. Average annual leakage rates in Europe are in the range of 15-20 % of the total charge. Worldwide the figure is about 30 % and HCFC-22 being the main refrigerant in use. Restrictions on the use of synthetic refrigerants are coming into force in several countries. There is a need for a natural refrigerant which allows for a safe investment in efficient refrigeration systems which will not be forced to be retrofitted by legislation in the future. Systems applying R744 as the only refrigerant have been developed and more than 300 supermarkets exist in Europe, mainly in northern and mid-European countries. However, the systems still have large potential in development with respect to energy efficiency, heat recovery and cost efficiency. The paper describes the calculation method to identify the possible annual energy savings for different supermarket systems layout. The adoption of ejector and additional function such as heat recovery are evaluated. Results show relevant improvements in system efficiency when heat recovery has been adopted. Ejector usage is not diffused at the moment. Thus, theoretical analysis has been carried out.
Documents disponibles
Format PDF
Pages : 11 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Development of commercial refrigeration systems with heat recovery for supermarket building.
- Identifiant de la fiche : 30004331
- Langues : Anglais
- Source : 10th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2012). Proceedings. Delft, The Netherlands, June 25-27, 2012.
- Date d'édition : 25/06/2012
Liens
Voir d'autres communications du même compte rendu (142)
Voir le compte rendu de la conférence
Indexation
-
Field data of CO2 integrated refrige...
- Auteurs : TOSATO G., MINETTO S., ROSSETTI A., HAFNER A., SCHLEMMINGER C., GIROTTO S.
- Date : 07/12/2020
- Langues : Anglais
- Source : 14th IIR-Gustav Lorentzen Conference on Natural Refrigerants (GL2020). Proceedings. Kyoto, Japon, December 7-9th 2020.
- Formats : PDF
Voir la fiche
-
Viable solutions to increase efficiencies of tr...
- Auteurs : HUFF H., FINCKH O., VERMA P., et al.
- Date : 25/06/2012
- Langues : Anglais
- Source : 10th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2012). Proceedings. Delft, The Netherlands, June 25-27, 2012.
- Formats : PDF
Voir la fiche
-
Thermo-economic design and optimization of a wa...
- Auteurs : MASTRULLO R., MAURO A. W., NAPOLI G., VISCITO L.
- Date : 21/08/2023
- Langues : Anglais
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
Voir la fiche
-
Untersuchung von CO2-Ejektoren beim Einsatz in ...
- Auteurs : FIORENZANO de ALBUQUERQUE R., TISCHENDORF C., LEMKE N., et al.
- Date : 06/2010
- Langues : Allemand
- Source : KI Kälte Luft Klimatechnik - vol. 46 - n. 6
Voir la fiche
-
Energetic and environmental performance evaluat...
- Auteurs : GULLO P., PUROHIT N., SANKARDASGUPTA M., et al.
- Date : 06/04/2018
- Langues : Anglais
- Source : 5th IIR International Conference on Sustainability and the Cold Chain. Proceedings: Beijing, Chine, 6-8 avril 2018
- Formats : PDF
Voir la fiche