Echangeur de chaleur ou régénérateur : une comparaison fondamentale.

Heat exchanger versus regenerator: a fundamental comparison.

Auteurs : WILL M. E., WAELE A. T. A. M. de

Type d'article : Article

Résumé

Irreversible processes in regenerators and heat exchangers limit the performance of cryocoolers. In this paper the authors compare the performance of cryocoolers, operating with regenerators and heat exchangers from a fundamental point of view. The losses in the two systems are calculated from the entropy productions due to the various irreversible processes. Whether an optimized regenerator or heat exchanger performs better depends on the system parameters (molar flux, temperature, and pressure). At temperatures below 200 K the losses due to heat conduction in the axial direction are dominant.

Détails

  • Titre original : Heat exchanger versus regenerator: a fundamental comparison.
  • Identifiant de la fiche : 2005-2393
  • Langues : Anglais
  • Source : Cryogenics - vol. 45 - n. 7
  • Date d'édition : 07/2005

Liens


Voir d'autres articles du même numéro (3)
Voir la source