Heat exchanger versus regenerator: a fundamental comparison.
Author(s) : WILL M. E., WAELE A. T. A. M. de
Type of article: Article
Summary
Irreversible processes in regenerators and heat exchangers limit the performance of cryocoolers. In this paper the authors compare the performance of cryocoolers, operating with regenerators and heat exchangers from a fundamental point of view. The losses in the two systems are calculated from the entropy productions due to the various irreversible processes. Whether an optimized regenerator or heat exchanger performs better depends on the system parameters (molar flux, temperature, and pressure). At temperatures below 200 K the losses due to heat conduction in the axial direction are dominant.
Details
- Original title: Heat exchanger versus regenerator: a fundamental comparison.
- Record ID : 2005-2393
- Languages: English
- Source: Cryogenics - vol. 45 - n. 7
- Publication date: 2005/07
Links
See other articles in this issue (3)
See the source
Indexing
- Themes: Small-scale cryogenic applications, cryocoolers
- Keywords: Thermodynamics; Regenerator; Cryocooler; Heat exchanger
-
Cryogenic regenerative heat exchangers.
- Author(s) : ACKERMANN R. A.
- Date : 1997
- Languages : English
View record
-
A simple regenerator test apparatus for testing...
- Author(s) : CHHATWAL H. L., GOSWAMI T. R., DIWAKAR R. K.
- Date : 1992/08
- Languages : English
- Source: Indian J. pure appl. Phys. - vol. 30 - n. 8
View record
-
Dynamic response of regenerator in cyclic flow ...
- Author(s) : HUANG B. J., LU C. W.
- Date : 1993/11
- Languages : English
- Source: Cryogenics - vol. 33 - n. 11
View record
-
Thermodynamic investigations of optimum active ...
- Author(s) : SMAÏLI A., CHAHINE R.
- Date : 1998/02
- Languages : English
- Source: Cryogenics - vol. 38 - n. 2
View record
-
Thermoacoustic theory for cyclic flow regenerat...
- Author(s) : XIAO J. H.
- Date : 1992
- Languages : English
- Source: Cryogenics - vol. 32 - n. 10
View record