Ecoulement d'isobutane à l'intérieur d'un tube capillaire non adiabatique.

Non-adiabatic capillary tube flow with isobutane.

Auteurs : MELO C., TORQUATO VIEIRA L. A., HORN-PEREIRA R.

Type d'article : Article

Résumé

This work reports the results of an experimental study on concentric capillary tube-suction line heat exchangers commonly used as expansion devices in household refrigerators and freezers. Heat exchanger performance with the hydrocarbon HC-600a was experimentally evaluated for a range of heat exchanger geometries and operating conditions. The tests were planned and performed following a statistically based methodology. Based on the resulting database empirical correlations were developed to predict the refrigerant mass flow rate and the suction line outlet temperature.

Détails

  • Titre original : Non-adiabatic capillary tube flow with isobutane.
  • Identifiant de la fiche : 2003-2810
  • Langues : Anglais
  • Source : Applied Thermal Engineering - vol. 22 - n. 14
  • Date d'édition : 10/2002

Liens


Voir d'autres articles du même numéro (6)
Voir la source