Effet de l'élimination des bio-contaminants dans une unité de conditionnement d'air compacte assistée par déshydratant liquide.
Removal effect of bio-contaminants in a packaged liquid desiccant-assisted air conditioning unit.
Numéro : pap. 2333
Auteurs : DONG H. W., JEONG J. W.
Résumé
The purpose of the study is to evaluate the removal effects of microbial contamination, such as fungi and bacteria, on a packaged liquid desiccant-assisted air conditioning unit. Recently, a package unit of a liquid desiccant and indirect and direct evaporative cooling-assisted 100% outdoor air system (LD-IDECOAS) was proposed. The LD-IDECOAS consists of a liquid desiccant system, an indirect evaporative cooler, and a direct evaporative cooler. The test was conducted under operating conditions during the cooling season when the LD-IDECOAS operates a liquid desiccant system, an indirect evaporative cooler, and a direct evaporative cooler. The sampling is performed ate the inlet (outdoor air) and outlet (supply air) of the package unit. Fungi were cultured in a potato dextrose agar (PDA) medium, and bacteria were cultured in a tryptic soy agar (TSA) medium as indices of bio-contaminants. The results indicated that the concentration of fungal contamination in the supply air (that passes through the package unit) decreased by 7.7% when compared to that of outdoor air. The concentration of bacterial contamination in the outlet was also reduced by 72.4% when compared to that in the inlet. Hence, the package unit improves air quality by removing bio-contaminants, such as fungi and bacteria, although unexpected contamination occurred in the experiment.
Documents disponibles
Format PDF
Pages : 10
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Removal effect of bio-contaminants in a packaged liquid desiccant-assisted air conditioning unit.
- Identifiant de la fiche : 30024508
- Langues : Anglais
- Source : 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Date d'édition : 09/07/2018
Liens
Voir d'autres communications du même compte rendu (252)
Voir le compte rendu de la conférence
Indexation
-
Mathematical model and performance analysis of ...
- Auteurs : PENG D., CHENG X., LI S., et al.
- Date : 10/2017
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 82
- Formats : PDF
Voir la fiche
-
Design and research on liquid dehumidification ...
- Auteurs : ZHU S., REN S., LIANG X.
- Date : 21/08/2007
- Langues : Anglais
- Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Formats : PDF
Voir la fiche
-
Effect of operation conditions on the second la...
- Auteurs : UCKAN I., YILMAZ T., BUYUKALACA O.
- Date : 25/02/2017
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 113
Voir la fiche
-
The seasonal performance of a liquid-desiccant ...
- Auteurs : LOWENSTEIN A., NOVOSEL D.
- Date : 01/1995
- Langues : Anglais
- Source : ASHRAE Transactions.
Voir la fiche
-
Étude pratique pour l’évaluation de la performa...
- Auteurs : ICHINOSE S., TANAKA H., USAMI Y., et al.
- Date : 09/2015
- Langues : Japonais
- Source : Transactions of the Society of Heating, Air-Conditioning and Sanitary Engineers of Japan - n. 222
Voir la fiche