Document IIF
Effet de la structure interne installée dans le réservoir sous pression dans la réaction de dismutation du HFO-1123.
Effect of internal structure installed in pressure vessel in HFO-1123 disproportionation reaction.
Résumé
Trifluoroethylene (HFO-1123) has been attracting considerable attention as a promising low-global-warming-potential refrigerant for new residential split air conditioners. However, if the refrigerant compressor short circuits, the disproportionation reaction of HFO-1123 may propagate under high-temperature and high-pressure conditions, which may lead to compressor explosion. Studies seeking to suppress the disproportionation reaction by adding refrigerants that do not cause the disproportionation HFO-1123 reaction have been performed; two refrigerant mixtures have been proposed as next-generation refrigerants. However, these mixtures could not suppress the disproportionation reaction under the worst condition (150 °C, 6.0 MPa) in practical use. Consequently, the difference in the reaction propagations between the experimental vessel and actual compressor for further suppression was investigated in this study. The experiment was conducted by introducing an internal part that mimics the actual compressor into the vessel. We investigated whether the flame ignited at the bottom of the vessel would pass through a small slit installed in the center and propagate to the entire vessel. The parameters were the volume of the ignition space and the width and thickness of the slit. When a combustion flame passes through a narrow gap, it may be cooled by a solid wall and extinguished. It was expected that the flame would be cooled and extinguished when passing through a narrow space, even in the disproportionation reaction. It was found that the reaction suppression effect was significant when the slit width was 1 mm or less.
Documents disponibles
Format PDF
Pages : 10-18
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Effect of internal structure installed in pressure vessel in HFO-1123 disproportionation reaction.
- Identifiant de la fiche : 30030596
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 145
- Date d'édition : 01/2023
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2022.09.030
Liens
Voir d'autres articles du même numéro (45)
Voir la source
Indexation
- Thèmes : HFO et HCFO
- Mots-clés : HFO; R1123; Structure; Pression; Faible GWP; Experimentation
-
pρT property measurements for HFO-1123 by a sin...
- Auteurs : KAYUKAWA Y.
- Date : 11/2020
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 119
- Formats : PDF
Voir la fiche
-
Suppression of disproportionation reaction of H...
- Auteurs : ZHANG Z., ITO M., DANG C., CHEN Y., HIHARA E.
- Date : 03/2021
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 123
- Formats : PDF
Voir la fiche
-
Characteristics of blends using ultra-low GWP m...
- Auteurs : SCHULTZ K., KUJAK S., SORENSON E.
- Date : 31/07/2020
- Langues : Anglais
- Source : IIR Rankine Conference 2020.
- Formats : PDF
Voir la fiche
-
Surface tension and parachor for a new low-GWP ...
- Auteurs : LIU Y., KONDOU C., COQUELET C., HOURIEZ C.
- Date : 12/2021
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 132
- Formats : PDF
Voir la fiche
-
Measurement of the vapor–liquid equilibrium pro...
- Auteurs : MIYAMOTO H., SAITO T., SAKODA N., PERERA U., ISHII T., THU K., HIGASHI Y.
- Date : 11/2020
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 119
- Formats : PDF
Voir la fiche