Document IIF
Mesurages des propriétés pρT du HFO-1123 à l’aide d’un densimètre à lévitation magnétique à plongeur unique.
pρT property measurements for HFO-1123 by a single sinker magnetic levitation densimeter.
Auteurs : KAYUKAWA Y.
Type d'article : Article de la RIF
Résumé
In order to develop a new refrigerant candidate to replace R410A or R32 used in domestic room air-conditioners, it is necessary to find novel substances with negligibly low GWP and low boiling-point temperatures. HFO-1123 (trifluoroethene) is one of the promising candidates because of its negligible GWP ( < 1) and slightly lower boiling-point temperature than R410A and R32. Although HFO-1123 has some disadvantages such as disproportionation reaction and weak flammability, it is expected to be a component of low-GWP refrigerant mixtures. In the present study, a set of vapor pressures and pρT properties of HFO-1123 was experimentally obtained. A single-sinker magnetic levitation densimeter (MLD) was used to obtain 57 gas-phase pρT properties at temperatures ranging from 260 K to 400 K. In the liquid-phase, 33 density data were obtained at temperatures from 260 K to 340 K and pressures up to 7 MPa. Based on the measurment results, a set of equations of state for single phase was developed.
Documents disponibles
Format PDF
Pages : 349-355
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : pρT property measurements for HFO-1123 by a single sinker magnetic levitation densimeter.
- Identifiant de la fiche : 30027821
- Langues : Anglais
- Sujet : Alternatives aux HFC
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 119
- Date d'édition : 11/2020
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2020.07.010
Liens
Voir d'autres articles du même numéro (41)
Voir la source
Indexation
-
Thèmes :
HFO et HCFO;
Mesures thermodynamiques - Mots-clés : HFO; R1123; Substitut; R410A; R32; Faible GWP; Masse volumique; Vapeur; Pression; Mesure; Experimentation; Conditionnement d'air
-
Surface tension and parachor for a new low-GWP ...
- Auteurs : LIU Y., KONDOU C., COQUELET C., HOURIEZ C.
- Date : 12/2021
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 132
- Formats : PDF
Voir la fiche
-
Saturated vapor pressure and gaseous pvT proper...
- Auteurs : YIN J., KE J., ZHAO G., MA S.
- Date : 09/2020
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 117
- Formats : PDF
Voir la fiche
-
Thermodynamic properties of trifluoroethene (R1...
- Auteurs : AKASAKA R., HIGASHI Y., SAKODA N., FUKUDA S., LEMMON E. W.
- Date : 11/2020
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 119
- Formats : PDF
Voir la fiche
-
Suppression of disproportionation reaction of H...
- Auteurs : ZHANG Z., ITO M., DANG C., CHEN Y., HIHARA E.
- Date : 03/2021
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 123
- Formats : PDF
Voir la fiche
-
Measurements of saturation pressures for the no...
- Auteurs : PERERA U., SAKODA N., MIYAZAKI T., THU K., HIGASHI Y.
- Date : 03/2022
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 135
- Formats : PDF
Voir la fiche