Document IIF
Mesurages des propriétés pρT du HFO-1123 à l’aide d’un densimètre à lévitation magnétique à plongeur unique.
pρT property measurements for HFO-1123 by a single sinker magnetic levitation densimeter.
Auteurs : KAYUKAWA Y.
Type d'article : Article de la RIF
Résumé
In order to develop a new refrigerant candidate to replace R410A or R32 used in domestic room air-conditioners, it is necessary to find novel substances with negligibly low GWP and low boiling-point temperatures. HFO-1123 (trifluoroethene) is one of the promising candidates because of its negligible GWP ( < 1) and slightly lower boiling-point temperature than R410A and R32. Although HFO-1123 has some disadvantages such as disproportionation reaction and weak flammability, it is expected to be a component of low-GWP refrigerant mixtures. In the present study, a set of vapor pressures and pρT properties of HFO-1123 was experimentally obtained. A single-sinker magnetic levitation densimeter (MLD) was used to obtain 57 gas-phase pρT properties at temperatures ranging from 260 K to 400 K. In the liquid-phase, 33 density data were obtained at temperatures from 260 K to 340 K and pressures up to 7 MPa. Based on the measurment results, a set of equations of state for single phase was developed.
Documents disponibles
Format PDF
Pages : 349-355
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : pρT property measurements for HFO-1123 by a single sinker magnetic levitation densimeter.
- Identifiant de la fiche : 30027821
- Langues : Anglais
- Sujet : Alternatives aux HFC
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 119
- Date d'édition : 11/2020
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2020.07.010
Liens
Voir d'autres articles du même numéro (41)
Voir la source
Indexation
-
Thèmes :
HFO et HCFO;
Mesures thermodynamiques - Mots-clés : HFO; R1123; Substitut; R410A; R32; Faible GWP; Masse volumique; Vapeur; Pression; Mesure; Experimentation; Conditionnement d'air
-
Measurement of the vapor–liquid equilibrium pro...
- Auteurs : MIYAMOTO H., SAITO T., SAKODA N., PERERA U., ISHII T., THU K., HIGASHI Y.
- Date : 11/2020
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 119
- Formats : PDF
Voir la fiche
-
Corrigendum to “Measurement of the vapor-liquid...
- Auteurs : MIYAMOTO H., SAITO T., SAKODA N., PERERA U., ISHII T., THU K., HIGASHI Y.
- Date : 04/2022
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 136
- Formats : PDF
Voir la fiche
-
Effect of internal structure installed in press...
- Auteurs : ZHANG Z., ITO M., DANG C., CHEN Y., HIHARA E.
- Date : 01/2023
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 145
- Formats : PDF
Voir la fiche
-
Characteristics of blends using ultra-low GWP m...
- Auteurs : SCHULTZ K., KUJAK S., SORENSON E.
- Date : 31/07/2020
- Langues : Anglais
- Source : IIR Rankine Conference 2020.
- Formats : PDF
Voir la fiche
-
Surface tension measurement for low GWP refrige...
- Auteurs : KONDOU C., HIGASHI Y.
- Date : 09/2018
- Langues : Anglais
- Source : 1st IIR international conference on the application of HFO refrigerants, Birmingham, September 2-5 2018.
- Formats : PDF
Voir la fiche