Effet de la température de saturation sur la condensation du R134a à l'intérieur d'un tube lisse incliné.
Effect of saturation temperature on the condensation of R134a inside an inclined smooth tube.
Auteurs : NOORI RAHIM ABADI S. M. A., MEHRABI M., MEYER J. P., et al.
Type d'article : Article, Article de la RIF
Résumé
In this study, numerical simulations of the condensation of R134a inside an inclined smooth tube are conducted. The effects of different parameters such as saturation temperature, tube inclination angle, vapour quality, and mass flux, on variations of the condensation heat transfer coefficient and pressure drop along the tube were investigated. The simulations were performed at a uniform heat flux of 5050 W/m2, mass fluxes of 100–400 kg/m2s, saturation temperatures of 30–50?°C, vapour qualities of 0.1–0.9, and inclination angles of -90 to + 90° It was assumed that the flow field was three-dimensional, transient, and turbulent. The volume of fluid model was used to solve the governing equations. The simulated results for the condensation heat transfer coefficient and pressure drop showed good correlation with the available experimental data. The results also demonstrated that the condensation heat transfer coefficient and pressure drop along the tube increased with decreasing saturation temperature, and increasing mass flux and vapour qualities. It was also determined that there was an optimum inclination-angle-range, -30 to -15°, in which the condensation heat transfer coefficient attained a maximum value.
Documents disponibles
Format PDF
Pages : 185-204
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Effect of saturation temperature on the condensation of R134a inside an inclined smooth tube.
- Identifiant de la fiche : 30025098
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 94
- Date d'édition : 10/2018
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2018.07.033
Liens
Voir d'autres articles du même numéro (19)
Voir la source
Indexation
-
Effect of saturation temperature change due to ...
- Auteurs : LEE H., JEONG J. H.
- Date : 09/07/2018
- Langues : Anglais
- Source : 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Numerical investigation on condensation heat tr...
- Auteurs : WEN J., GU X., WANG S., et al.
- Date : 01/2018
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 85
- Formats : PDF
Voir la fiche
-
Condensation characteristics of R134A and R404A...
- Auteurs : KUKREJA R., SINGH S.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche
-
An experimental study of pressure drop characte...
- Auteurs : GUPTA A., KUMAR R.
- Date : 17/06/2013
- Langues : Anglais
- Source : 4th IIR Conference on Thermophysical Properties and Transfer Processes of Refrigerants
- Formats : PDF
Voir la fiche
-
Flow patterns, heat transfer and pressure drop ...
- Auteurs : COLOMBO L. P. M., LUCCHINI A., MUZZIO A.
- Date : 12/2012
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 35 - n. 8
- Formats : PDF
Voir la fiche