Document IIF

Effet des défauts d'installation sur la performance d'un conditionneur d'air split.

Effect of installation faults on the performance of a split air conditioner.

Numéro : pap. n. 597

Auteurs : DOMANSKI P. A., HENDERSON H. I., PAYNE W. V.

Résumé

The study analyzed the effect of common installation faults on the cooling performance of a residential, split air conditioner installed in a single-family, slab-on-grade house. We considered five climatic regions in the United States from hot/humid to cold. Through seasonal simulations of the house/air conditioner system, the study found that duct leakage, refrigerant undercharge, undersized refrigerant expansion valve, low indoor airflow, and air conditioner oversizing with non-oversized ductwork have the most potential for causing significant performance degradation and increased seasonal energy consumption. Seasonal energy use can significantly increase even more when the homeowner lowers the thermostat setting to remove excessive indoor humidity caused by certain installation faults.

Documents disponibles

Format PDF

Pages : 8 p.

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Effect of installation faults on the performance of a split air conditioner.
  • Identifiant de la fiche : 30015697
  • Langues : Anglais
  • Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
  • Date d'édition : 16/08/2015
  • DOI : http://dx.doi.org/10.18462/iir.icr.2015.0597

Liens


Voir d'autres communications du même compte rendu (657)
Voir le compte rendu de la conférence