Résumé
The study investigates the two-phase flow characteristics of refrigerant R22 in T-branch with horizontal and vertical inlet tube. The key experimental parameters were the orientation of inlet and branch tubes (horizontal, vertical upward and vertical downward), diameter ratio of branch tube to inlet tube, inlet mass flux and inlet quality. Predicted pressure profile agreed with the measured data within 25.4%. The flow distribution ratio decreased as the mass flux increased. The flow distribution ratio decreased by 12-25% as the tube diameter ratio decreased from 1 to 0.61, and decreased by 38-47% as the orientation of branch changed from horizontal to vertical upward for horizontal inlet tubes. As the orientation of inlet tube changed from horizontal to vertical upward for horizontal branch, the flow distribution ratio increased by 15-68%, whereas it changed from horizontal to vertical downward, the flow distribution ratio decreased by 19-45% due to the gravity effect.
Documents disponibles
Format PDF
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Effect of geometric and dynamic parameters on the two-phase flow distribution of R22 in branch tubes.
- Identifiant de la fiche : 2004-2215
- Langues : Anglais
- Source : 21st IIR International Congress of Refrigeration: Serving the Needs of Mankind.
- Date d'édition : 17/08/2003
Liens
Voir d'autres communications du même compte rendu (398)
Voir le compte rendu de la conférence
-
Caractéristiques d'écoulement et de transfert d...
- Auteurs : HORIBE A.
- Date : 02/2005
- Langues : Japonais
- Source : Refrigeration - vol. 80 - n. 928
Voir la fiche
-
Experimental research on resistance loss and he...
- Auteurs : ZHANG X. L., SHENG Q. Q., YE J., et al.
- Date : 05/04/2008
- Langues : Anglais
- Source : Cryogenics and refrigeration. Proceedings of ICCR'2008.
Voir la fiche
-
Experimental investigation of two-phase pressur...
- Auteurs : PADILLA M., REVELLIN R., HABERSCHILL P., et al.
- Date : 16/06/2010
- Langues : Anglais
- Source : RCR 2010. 2nd IIR Workshop on Refrigerant Charge Reduction in Refrigerating Systems: Stockholm, Sweden, June 16-17, 2010.
- Formats : PDF
Voir la fiche
-
Experimental study of two-phase pressure-drop i...
- Auteurs : MUZAFFAR A., ABBAS A., CREMASCHI L., AYUB Z.
- Date : 12/2024
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 168
- Formats : PDF
Voir la fiche
-
Two-phase pressure drop in return bends: experi...
- Auteurs : PADILLA M., REVELLIN R., HABERSCHILL P., et al.
- Date : 12/2011
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 34 - n. 8
- Formats : PDF
Voir la fiche