Effet des variations saisonnières sur la performance thermique d'un échangeur de chaleur géothermique à boucle horizontale mince.
The effect of seasonal variation on thermal performance of horizontal slinky loop ground heat exchanger.
Numéro : pap. 3447
Auteurs : SELAMAT S., MIYARA A.
Résumé
For ground-source heat pump (GSHP) installations, it is important to predict the thermal performance and economic feasibility prior to the introduction of the system. Numerical modelling can be used as an analytical method to accurately predict the thermal performance of such system. It is desirable that the modelling to incorporate seasonal variation during long period of operation, which would lead to a better understanding of the overall performance and provide more reliable results. In this work, numerical modelling performed using computational fluid dynamic software presented the heat exchange rate for different operation of slinky loop ground heat exchanger (GHE) using time- and position-varying parameters. Each operation were carried out in short and long simulation periods during winter and summer conditions of southwest of Japan, specifically in Saga City. This analysis suggested that heat flow in GHE operation was more dominant along vertical axis. It also supports the common claim that heat exchange rate is predominantly limited by the thermal conductivity of the ground. Spaced loops in multiple parallel GHE helped to minimize the interference of heat flow that would penalize the overall thermal performance.
Documents disponibles
Format PDF
Pages : 10 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : The effect of seasonal variation on thermal performance of horizontal slinky loop ground heat exchanger.
- Identifiant de la fiche : 30013720
- Langues : Anglais
- Source : 2014 Purdue Conferences. 3rd International High Performance Buildings Conference at Purdue.
- Date d'édition : 14/07/2014
Liens
Voir d'autres communications du même compte rendu (66)
Voir le compte rendu de la conférence
Indexation
-
High efficient heat pump system using storage t...
- Auteurs : ROTHUIZEN E., ELMEGAARD B., MARKUSSEN W. B., et al.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche
-
Heat pump performance sensitivity to horizontal...
- Auteurs : BURKE N., GREENE M., LOHAN J., et al.
- Date : 20/05/2008
- Langues : Anglais
- Source : 9th IEA Heat Pump Conference 2008: advances and prospects in technology, applications and markets. Conference proceedings [CD-ROM + abstracts].
Voir la fiche
-
Performance assessment of the porous solid supp...
- Auteurs : TSUMAGARI S., WATANABE F., HASATANI M., et al.
- Date : 17/02/2010
- Langues : Anglais
- Source : Measures to address climate change. 2010 International Symposium on Next-generation Air Conditioning and Refrigeration Technology: February 17-19, Tokyo, Japan.
- Formats : PDF
Voir la fiche
-
Experimental study of heat transfer of borehole...
- Auteurs : QIAN H., REN Q., ZHANG X., et al.
- Date : 21/08/2011
- Langues : Anglais
- Source : Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
- Formats : PDF
Voir la fiche
-
Numerical simulation of ground heat and water t...
- Auteurs : NAM Y., OOKA R.
- Date : 20/05/2008
- Langues : Anglais
- Source : 9th IEA Heat Pump Conference 2008: advances and prospects in technology, applications and markets. Conference proceedings [CD-ROM + abstracts].
Voir la fiche