Document IIF
Effets de l'injection du frigorigène liquide sur la performance d'un système frigorifique muni d'un échangeur de chaleur à accumulation.
Effects of liquid refrigerant injection on the performance of a refrigeration system with an accumulator heat exchanger.
Résumé
Liquid refrigerant injection technique can be a very effective method for controlling subcooling and the compressor discharge temperature of a refrigeration system at high ambient temperatures. In this study, the effects of liquid refrigerant injection on the performance of a refrigeration system with an accumulator heat exchanger were investigated by varying the liquid injection rate at the conditions of constant expansion valve opening in the evaporator and constant total flow rate. During the tests, the ambient temperature was maintained at 43°C. With the increase of the liquid injection rate, the subcooling at the inner heat exchanger outlet increased and the superheat at the accumulator outlet decreased. However, unacceptable results such as the increase of the compressor discharge pressure and decrease of the system performance were also observed depending on the control method applied. To obtain high system performance and reliability, optimum control methods for liquid injection in the accumulator heat exchanger are suggested. The liquid injection technique for the refrigeration system with an accumulator heat exchanger was found to be an effective method for controlling adequate subcooling and the compressor discharge temperature of the refrigeration system at high ambient temperatures.
Documents disponibles
Format PDF
Pages : 883-891
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Effects of liquid refrigerant injection on the performance of a refrigeration system with an accumulator heat exchanger.
- Identifiant de la fiche : 2008-1613
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 31 - n. 5
- Date d'édition : 08/2008
Liens
Voir d'autres articles du même numéro (19)
Voir la source
Indexation
-
Performance comparison between bypass cycle and...
- Auteurs : MIN B., JANG S., LEE T., et al.
- Date : 11/2019
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 107
- Formats : PDF
Voir la fiche
-
Sierra condensing unit uses a smaller refrigera...
- Date : 12/06/1995
- Langues : Anglais
- Source : Air Cond. Heat. Refrig. News - vol. 195 - n. 7
Voir la fiche
-
Experimental evaluation of a CO2 transcritical ...
- Auteurs : LLOPIS R., NEBOT-ANDRÉS L., CABELLO R., et al.
- Date : 09/2016
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 69
- Formats : PDF
Voir la fiche
-
Les mesures : sous-refroidissement. Fiche prati...
- Auteurs : JACQUARD P.
- Date : 05/1998
- Langues : Français
- Source : La revue pratique du froid et du conditionnement d'air - n. 857
Voir la fiche
-
Les aérofrigorifères à fluide frigoporteur.
- Auteurs : PONSOT M.
- Date : 10/1994
- Langues : Français
- Source : Rev. gén. Froid - vol. 84 - n. 947
Voir la fiche