Effets des différentes conceptions de lit adsorbeur sur les mesures in-situ du taux d'absorption d'eau de AQSOA FAM-Z02 pour les applications de conditionnement d'air de véhicule.
Effects of different adsorber bed designs on in-situ water uptake rate measurements of AQSOA FAM-Z02 for vehicle air conditioning applications.
Auteurs : SHARAFIAN A., NEMATI MEHR S. M., HUTTEMA W., et al.
Type d'article : Article
Résumé
Adsorption cooling systems (ACS) utilize waste heat to produce the cooling power required for air conditioning (A/C) in vehicles. In addition to having an adsorbent with high adsorbate uptake rate and thermal conductivity, different adsorber bed designs can significantly affect the performance of an ACS. In this study, the water uptake rate of AQSOA FAM-Z02 packed in two different adsorber beds is measured in-situ under adsorption and desorption temperatures of 30 and 90?°C, and the water vapor supplied at 20?°C. The effects of some parameters, such as changes in the density of heat transfer fluid and stiffness of flexible hosing connected to the adsorber bed, show significant contribution in the adsorbate uptake mass measurements. To de-convolute these undesirable effects, a two-step mass measurement is performed to precisely measure the adsorbate uptake rate. To verify the developed method, the equilibrium water uptakes of AQSOA FAM-Z02 are measured and compared against the available data in the literature measured by a thermogravimetric analysis. Next, the water uptake of AQSOA FAM-Z02 is measured for different cycle times, followed by calculation of specific cooling power (SCP) and coefficient of performance (COP). Results show that high heat transfer surface area and small fin spacing are the main specifications of a well-designed adsorber bed for ACS applications. As a result of using AQSOA FAM-Z02 and a well-designed adsorber bed, a SCP of 112.9 W/kg and a COP of 0.34 are achieved at cycle time of 10?min.
Détails
- Titre original : Effects of different adsorber bed designs on in-situ water uptake rate measurements of AQSOA FAM-Z02 for vehicle air conditioning applications.
- Identifiant de la fiche : 30017613
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 98
- Date d'édition : 05/04/2016
- DOI : http://dx.doi.org/10.1016/j.applthermaleng.2015.12.060
Liens
Voir d'autres articles du même numéro (61)
Voir la source
Indexation
-
Application du froid à adsorption solide dans l...
- Auteurs : MA G., LI J. H.
- Date : 03/2004
- Langues : Chinois
- Source : Refrigeration - vol. 86 - n. 1
Voir la fiche
-
Construction and testing of a wet-compression a...
- Auteurs : NIU Y., CHEN J., CHEN Z., et al.
- Date : 01/2007
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 27 - n. 1
Voir la fiche
-
Simulation of absorption refrigeration system f...
- Auteurs : RAMANATHAN A., GUNASEKARAN P.
- Date : 2008
- Langues : Anglais
- Source : Rev. gén. Therm./Int. J. therm. Sci. - vol. 12 - n. 3
Voir la fiche
-
A double-effect hybrid vehicular air-conditioni...
- Auteurs : LIU Z. B., HAO Y. T., WANG Z. M., et al.
- Date : 21/08/2007
- Langues : Anglais
- Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Formats : PDF
Voir la fiche
-
Design and performance analysis of function pro...
- Auteurs : QIN F., CHEN J. P., LU M. Q., et al.
- Date : 29/05/2006
- Langues : Anglais
- Source : 7th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2006). Proceedings
- Formats : PDF
Voir la fiche