Effets sonores de l’écoulement du frigorigène dans les tubes capillaires.
Noise effects in capillary tubes caused by refrigerant flow.
Numéro : pap. 2009
Auteurs : TANNERT T., HESSE U.
Résumé
The preferred cooling process for household refrigeration appliances is a vapor compression refrigeration process with a capillary tube as expansion device. The vapor compression refrigeration system requires a phase change of the refrigerant inside the condenser and evaporator. The condenser outlet defines directly the refrigerant state at the capillary tube inlet through a direct connection of condenser outlet and capillary tube inlet. This is commonly practiced for household refrigeration systems. Due to unsteady operation conditions the refrigerant state can change from subcooled liquid to saturated liquid with partially a vapor phase at the capillary tube inlet. The refrigerant flow inside the capillary tube is either adiabatic or non-adiabatic (by utilizing internal heat exchange). In both cases the refrigerants state of matter changes during the expansion with an increase of vapor quality towards the capillary tube outlet. A variable vapor quality at the capillary tube inlet causes different flow patterns, especially at the capillary tube outlet. These flow patterns change periodically depending on the refrigerant state of matter at the capillary tube inlet. Associated with the periodical changing flow patterns the occurrence of noise effects with the same periodicity and remarkable variations of the sound pressure level can be observed at the capillary tube outlet. This paper presents the experimental investigations on the simultaneous occurrence of refrigerant flow patterns and corresponding noise effects at the outlet of a capillary tube installed in a refrigeration test cycle. The discussion of the experimental results leads to an explanation of causal relation between distinguishable flow patterns and corresponding noise effects.
Documents disponibles
Format PDF
Pages : 10 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Noise effects in capillary tubes caused by refrigerant flow.
- Identifiant de la fiche : 30018765
- Langues : Anglais
- Source : 2016 Purdue Conferences. 16th International Refrigeration and Air-Conditioning Conference at Purdue.
- Date d'édition : 11/07/2016
Liens
Voir d'autres communications du même compte rendu (274)
Voir le compte rendu de la conférence
-
Massflow fluctuation in capillary tubes of hous...
- Auteurs : TANNERT T., HESSE U.
- Date : 21/08/2016
- Langues : Anglais
- Source : 12th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2016). Proceedings. Édimbourg, United Kingdom, August 21st-24th 2016.
- Formats : PDF
Voir la fiche
-
The effect of biphasic refrigerant flow on refr...
- Auteurs : VENDRAMI C. E., MIGUEL E., SOUZA D. de, et al.
- Date : 09/07/2018
- Langues : Anglais
- Source : 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Numerical modelling and experimental investigat...
- Auteurs : LIU Y. C., CAO L. H., YANG Z. H., et al.
- Date : 05/04/2008
- Langues : Anglais
- Source : Cryogenics and refrigeration. Proceedings of ICCR'2008.
Voir la fiche
-
Noise generation in household refrigerators: an...
- Auteurs : BOABAID NETO C., MELO C., LENZI A., et al.
- Date : 14/07/2014
- Langues : Anglais
- Source : 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Visualization of the refrigerant flow at the ca...
- Auteurs : MARTÍNEZ-BALLESTER S., BARDOULET L., PISANO A., et al.
- Date : 14/07/2014
- Langues : Anglais
- Source : 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche