Encrassage du côté air d'un évaporateur : effet sur la performance des conditionneurs d'air et impact sur la qualité de l'air intérieur.
Evaporator air-side fouling: effect on performance of room air conditioners and impact on indoor air quality.
Auteurs : ALI A. H. H., ISMAIL I. M.
Type d'article : Article
Résumé
This study investigated experimentally the effects of real fouling material at the air side of the evaporator's heat exchanger coil on the performance of room air-conditioner units as well as the impact of some fouling material compositions on indoor air quality. At the end of the experiments, examination of the biological contents of the fouling material on the coil was performed; it was found that the coil frontal face had heavy colonies of Aspergillus fungi of different species. This result is important to fill in the knowledge gaps between biological deposition, colonization, and occupant problems of staying in an environment with a fouled evaporator coil. The results of the effect of such fouling materials on the unit performance show that the unit COP at the standard air face velocity of 1.53 m/s for a clean evaporator coil was 2.82. It decreased to 1.89 (67%) after injection of 100 g of fouling materials, dropped to 1.79 (63.4%) after injection of 200 g of fouling materials, and fell to 1.23 (43.6%) after injection of 300 g of fouling materials. However, these results demonstrate that the predominant effect of fouling is to cause significant degradation in a room air conditioner's COP.
Détails
- Titre original : Evaporator air-side fouling: effect on performance of room air conditioners and impact on indoor air quality.
- Identifiant de la fiche : 2008-1707
- Langues : Anglais
- Source : HVAC&R Research - vol. 14 - n. 2
- Date d'édition : 03/2008
Liens
Voir d'autres articles du même numéro (6)
Voir la source
Indexation
-
Air-side fouling of finned heat exchangers: Par...
- Auteurs : INAMDAR H. V., GROLL E. A., WEIBEL J. A., GARIMELLA S. V.
- Date : 07/2023
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 151
- Formats : PDF
Voir la fiche
-
Air-side fouling of finned heat exchangers: Par...
- Auteurs : INAMDAR H. V., GROLL E. A., WEIBEL J. A., GARIMELLA S. V.
- Date : 07/2023
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 151
- Formats : PDF
Voir la fiche
-
An experimental study of the air-side particula...
- Auteurs : AHN Y. C., CHEONG S. I., JUNG Y. M., et al.
- Date : 17/07/2006
- Langues : Anglais
- Source : 2006 Purdue Conferences. 18th International Compressor Engineering Conference at Purdue & 11th International Refrigeration and Air-Conditioning Conference at Purdue [CD-ROM].
- Formats : PDF
Voir la fiche
-
Humidity and cycle period effect on hygroscopic...
- Auteurs : LUO W. J., LU C. W., CHENG Y. S., et al.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche
-
Cycle performance of air conditioning system ba...
- Auteurs : WANG S., KE H., LI X., et al.
- Date : 03/2015
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 78
Voir la fiche