Document IIF
Energy and exergy analysis and optimization studies of a CO2/NH3 cascade refrigeration system.
Numéro : pap. n. 45
Auteurs : YILMAZ B., ERDONMEZ N., ÖZYURT A., et al.
Résumé
The harmful effects of synthetic refrigerants on ozone depletion result in replacing them with natural refrigerants such as carbon dioxide. Carbon dioxide (CO2) may be used in a single trans-critical cycle or it may be utilized as a refrigerant of the low temperature cycle of a cascade system. In such cascade systems, as a promising method, ammonia may be used in the high temperature cycle side. In this study, thermodynamic analysis of a cascade refrigeration system using CO2 (R744) and NH3 (R717) refrigerants in the low and high temperature cycles is presented. The energy and exergy analysis of the system with its components are performed to determine optimum operating conditions for condensing and evaporation temperature of the cascade condenser. The coefficient of performance is calculated using the developed numerical model in Engineering Equation Solver (EES) software. The linear regression method is applied to obtain optimum cascade condensing temperatures for different operating conditions.
Documents disponibles
Format PDF
Pages : 8 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Energy and exergy analysis and optimization studies of a CO2/NH3 cascade refrigeration system.
- Identifiant de la fiche : 30014680
- Langues : Anglais
- Source : 6th Conference on Ammonia and CO2 Refrigeration Technology. Proceedings: Ohrid, North Macedonia, April 16-18, 2015.
- Date d'édition : 16/04/2015
Liens
Voir d'autres communications du même compte rendu (53)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
Systèmes à compression;
Ammoniac;
CO2 - Mots-clés : Exergie; Énergie; R744; Ammoniac; Optimisation; Système en cascade; Frigorigène; CO2
-
Exergetic, economic and environmental (3E) anal...
- Auteurs : AMINYAVARI M., NAJAFI B., SHIRAZI A., et al.
- Date : 04/2014
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 65 - n. 1-2
Voir la fiche
-
Thermodynamic analysis of an R-744/R-717 cascad...
- Auteurs : GETU H. M., BANSAL P. K.
- Date : 01/2008
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 31 - n. 1
- Formats : PDF
Voir la fiche
-
Exergetic analysis of refrigeration cycles oper...
- Auteurs : FILIPOIU C., DOBROVICESCU A., APOSTOL V., et al.
- Date : 09/05/2013
- Langues : Anglais
- Source : 5th Conference on Ammonia Refrigeration Technology. Proceedings: Ohrid, North Macedonia, May 9-11, 2013.
- Formats : PDF
Voir la fiche
-
Theoretical study and design of small-scale cas...
- Auteurs : PETRENKO V. O., HUANG B. J., SHESTOPALOV K. O., et al.
- Date : 07/06/2010
- Langues : Anglais
- Source : ACRA2010. Asian conference on refrigeration and air conditioning: Tokyo, Japan, June 7-9, 2010.
- Formats : PDF
Voir la fiche
-
Thermodynamic analysis and optimization of casc...
- Auteurs : YILMAZ B., ERDONMEZ N., SEVINDIR M. K., et al.
- Date : 14/07/2014
- Langues : Anglais
- Source : 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche