Résumé
Because of the multiple problems on high energy consumption and unbalanced thermal comfort caused by the traditional ventilation system, a new concept of ventilation (stratum ventilation) has been proposed which sends the fresh air to the breathing zone directly. In this paper the local air distribution of the displacement ventilation and the stratum ventilation in a model office were measured. The air age in the breathing zone for the displacement ventilation and stratum ventilation were compared with the tracer gas concentration decay method. The decay curves of tracer gas concentration for these two ventilation systems in the breathing zone were obtained and the air ages were calculated. The experimental results show that the stratum ventilation system can offer lower air age for four mechanically ventilated cases in the breathing zone, furthermore, it can provide better thermal comfort, which renews the air of breathing zone more quickly and reduces the energy consumption in some degree. The experimental investigation provides a theoretical basis for the application of a stratum ventilation system.
Documents disponibles
Format PDF
Pages : pp. 512-517
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Experimental investigation on the local air age and air distribution of stratum ventilation.
- Identifiant de la fiche : 2010-0886
- Langues : Anglais
- Source : ACRA-2009. The proceedings of the 4th Asian conference on refrigeration and air conditioning: May 20-22, 2009, Taipei, R.O.C.
- Date d'édition : 20/05/2009
Liens
Voir d'autres communications du même compte rendu (102)
Voir le compte rendu de la conférence
Indexation
-
New AC system aims to revolutionise Australian ...
- Date : 03/2005
- Langues : Anglais
- Source : Climate Control News - vol. 4 - n. 3
Voir la fiche
-
Airflow dilemmas solved with an UFAD system.
- Auteurs : REES J. A.
- Date : 03/2006
- Langues : Anglais
- Source : HPAC Engineering - vol. 78 - n. 3
Voir la fiche
-
Displacement ventilation forming at different a...
- Auteurs : TRZECIAKIEWICZ Z., POPIOLEK Z., MIERZWINSKI S.
- Date : 09/08/1999
- Langues : Anglais
Voir la fiche
-
Conception du point de vue CVC de piscines dans...
- Auteurs : MA Y., LI J., ZHANG B.
- Date : 11/2013
- Langues : Chinois
- Source : HV & AC - vol. 43 - n. 284
- Formats : PDF
Voir la fiche
-
Multi-service chilled beams (MSCBs) at the Empr...
- Auteurs : HUTCHINS G., PENNELL N.
- Date : 24/09/2003
- Langues : Anglais
Voir la fiche