Estimation des paramètres de transfert d’un tissu quelconque non absorbant et application à des systèmes à déshydratant liquide.
Estimating carryover parameters of a non-wicking random weave fabric - with applications to liquid desiccant systems.
Numéro : 2613
Auteurs : FALLOWS S., MULLER M., ROSSI D.
Résumé
Liquid desiccant dehumidification is an energy-saving alternative to conventional vapor-compression dehumidification. Liquid desiccant systems can be designed in various manners, with one of the common system types consisting of air and desiccant in crossflow. The carryover of liquid desiccant droplets is unwanted as it loses material, can cause corrosion, and depending on the liquid desiccant can reduce the breathable air quality in HVAC applications. The integration of fabrics as a primary conduit for desiccant flow is common to improve performance and reduce carryover. A benchtop scale falling film crossflow liquid desiccant system was constructed to study the entrainment of liquid desiccant droplets sheared from a fabric by an air stream. Additionally, an investigation was conducted to define the critical characteristics of a fabric relevant to the carryover of liquid desiccant droplets. The desiccant “bulge” profiles pushing out of the fabric’s pores were modeled to identify the onset of carryover. Results show that the key non-dimensional parameter (Weber number) predicts no carryover for We <= 10.
Documents disponibles
Format PDF
Pages : 11 p.
Disponible
Gratuit
Détails
- Titre original : Estimating carryover parameters of a non-wicking random weave fabric - with applications to liquid desiccant systems.
- Identifiant de la fiche : 30033019
- Langues : Anglais
- Sujet : Technologie
- Source : 2024 Purdue Conferences. 20th International Refrigeration and Air-Conditioning Conference at Purdue.
- Date d'édition : 17/07/2024
Liens
Voir d'autres communications du même compte rendu (104)
Voir le compte rendu de la conférence
Indexation
-
Performance characteristics for a desiccant sys...
- Auteurs : VINEYARD E. A., SAND J. R., DURFEE D. J.
- Date : 2002
- Langues : Anglais
- Source : ASHRAE Transactions. 2002 Winter Meeting, Atlantic City, New Jersey. Volume 108, part 1 + CD-ROM.
Voir la fiche
-
Parametric study of an energy efficient air con...
- Auteurs : KINSARA A. A., RABGHI O. M. al-, ELSAYED M. M.
- Date : 05/1998
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 18 - n. 5
Voir la fiche
-
Open cycle adsorption cooling system with a the...
- Auteurs : KODAMA A., JIN W., GOTO M., HIROSE T.
- Date : 24/05/1998
- Langues : Anglais
- Source : Fundamentals of adsorption - FOA6. Proceedings of the Sixth International Conference.
Voir la fiche
-
Performance analysis of a combined desiccant/ab...
- Auteurs : SCHINNER E. N., RADERMACHER R.
- Date : 01/1999
- Langues : Anglais
- Source : HVAC&R Research - vol. 5 - n. 1
Voir la fiche
-
A simple performance evaluator of desiccant coo...
- Auteurs : MAZZEI P., MINICHIELLO F., PALMA D.
- Date : 01/04/2001
- Langues : Anglais
- Source : Arab-African Conference for Refrigeration and Air Conditioning.
Voir la fiche