Étude de faisabilité d'un échangeur de chaleur à tubes de 5mm et ailettes dans un système automobile avec pompe à chaleur.

[In Chinese. / En chinois.]

Auteurs : WEI W., ZHAO Y., CHEN J., et al.

Type d'article : Article

Résumé

The parallel flow microchannel (PFM) heat exchanger is widely used in automotive air conditioning system, but it has the disadvantage of frost easily and water draining is difficult during defrost. The traditional tube and fin heat exchanger can overcome the frost and defrost problem but has low efficiency. In this paper a 05 tube and fin heat exchanger is developed for the automotive heat pump. Performances of small diameter tube-and-fin heat exchanger and PFM heat exchanger are compared based on a benchmark test. Results show that the system with the small diameter tube-and-fin heat exchanger has 17.4%-23.7% higher COP in air conditioning mode, 12.6%- 35.8% higher COP and 15- 28 °C lower compressor discharge temperature in heat pump mode, which indicates that small diameter tube-and-fin heat exchanger is a promising solution for the automotive heat pump system of electric vehicles.

Documents disponibles

Format PDF

Pages : 35-39

Disponible

  • Prix public

    20 €

  • Prix membre*

    15 €

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails


Liens


Voir d'autres articles du même numéro (9)
Voir la source