Étude de l’utilisation efficace du glissement de température et d’un échangeur de chaleur interne en vue d’améliorer les performances des systèmes de conditionnement d’air et des pompes à chaleur.
Investigation on the effective use of glide and a suction-line liquid-line heat exchanger to improve performance in air conditioning and heat pump.
Numéro : 2262
Auteurs : KIMURA DE CARVALHO B. Y., SETHI A., RACHED W.
Résumé
The escalating demand for low-GWP, high-efficiency refrigerants in air conditioning and heat pump applications has driven the adoption of blends capable of meeting technical and performance criteria. Zeotropic compositions, characterized by temperature glide, may necessitate heat exchanger redesign to counter pinching effects. However, this unique property presents an opportunity for performance enhancement. Leveraging the refrigerant glide, particularly in areas where a constant saturation temperature cannot suffice, offers a promising avenue for improvement.
This investigation explores the use of multi-row coils to align the glide with the temperature lift of the air and introduces the use of a suction-line liquid-line heat exchanger (SLHX) to exploit the glide to improve evaporator performance. Thermodynamic properties of HFO-based refrigerants show a need to increase overall heat transfer area and compressor displacement to match COP and capacity of R410A. By designing heat exchangers around a cross-counter flow arrangement and proper circuitry it’s possible to achieve similar performance to R32. Through modeling, the study assesses the impact of SLHX on pure (R32) and zeotropic (R454C) refrigerants. The results demonstrate significant performance enhancement for R454C, attributed to the relocation of the higher temperature saturation region from the evaporator to the SLHX. This enables operation at higher suction pressures without encountering evaporator pinching. The findings underscore the potential of SLHX in optimizing refrigerant performance, particularly in zeotropic compositions, for enhanced efficiency in air conditioning and heat pump systems.
Documents disponibles
Format PDF
Pages : 10 p.
Disponible
Gratuit
Détails
- Titre original : Investigation on the effective use of glide and a suction-line liquid-line heat exchanger to improve performance in air conditioning and heat pump.
- Identifiant de la fiche : 30033099
- Langues : Anglais
- Sujet : Technologie
- Source : 2024 Purdue Conferences. 20th International Refrigeration and Air-Conditioning Conference at Purdue.
- Date d'édition : 17/07/2024
Liens
Voir d'autres communications du même compte rendu (187)
Voir le compte rendu de la conférence
Indexation
-
Refrigerants: wise-up to the impact of glide on...
- Auteurs : HUNDY G.
- Date : 01/2000
- Langues : Anglais
- Source : S. afr. Inst. Refrig. Air Cond. - vol. 102 - n. 1222
Voir la fiche
-
Refrigerant blends for air conditioning: causes...
- Auteurs : MORLEY J. R.
- Date : 2004
- Langues : Anglais
- Source : Annual proceedings of the Institute of Refrigeration. 2003-2004 [CD-ROM].
Voir la fiche
-
Experimental investigation of high-glide refrig...
- Auteurs : BRENDEL L. P. M., BERNAL S. N., ARPAGAUS C., WIDMAIER P., ROSKOSCH D., BARDOW A., BERTSCH S. S.
- Date : 21/08/2023
- Langues : Anglais
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
Voir la fiche
-
Vapor compression heat pumps with refrigerant m...
- Auteurs : LING J., HWANG Y., RADERMACHER R.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche
-
The new wave of blends.
- Auteurs : HALE J., MCKINNEY G.
- Date : 03/02/2003
- Langues : Anglais
- Source : Air Cond. Heat. Refrig. News/achrnews.com - 4 p.