This work studies the performance of a refrigerator with a DC compressor motor using Butane as refrigerant, (R600) and PV module as a power source controlled by a battery. This R 600 was used as drop – in refrigerant to replace the original R 134a refrigerant. The refrigerator rated power is 60 Watts, the battery capacity is 21 Amper hour, (Ah), 12 V, connected to either a 70 Wp module or a 100 Wp module. The experiments were carried out using five different conditions for the power connection: battery stand alone with no PV connection; battery fully charged and either connected to the 70 Wp module or the 100 Wp module; and un charged battery connected to either the 100 Wp module or the 70 Wp module. The states of on-off conditions and their effect on the refrigerator inside temperatures and the refrigeration performance parameters settings of evaporation temperature and condensing temperature were mainly monitored in this study. The effect of the low power trips on-off sequence of the refrigerator on the freezer inside temperature and on the load temperatures was one of the main objectives of this study. This study showed that the minimum module capacity that can power the refrigerator with out interruption of the cooling process of the load was the 100 Wp.
Documents disponibles
Format PDF
Pages : 10 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Performance study of a DC refrigerator powered by different solar PV modular sets. 2.
- Identifiant de la fiche : 30015542
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Date d'édition : 16/08/2015
- DOI : http://dx.doi.org/10.18462/iir.icr.2015.0740
Liens
Voir d'autres communications du même compte rendu (657)
Voir le compte rendu de la conférence
Indexation
-
ABAISSEMENT DE LA CONSOMMATION D'ENERGIE DES AR...
- Auteurs : ANDRJUSCENKO A. G., VLADIMIROV V. N., SUGAEPOV N. S.
- Date : 1990
- Langues : Russe
- Source : Kholodilnaya Tekhnika - n. 5
Voir la fiche
-
PERFORMANCE TESTING OF REFRIGERATED CABINETS.
- Auteurs : KOK H. J. G., LAAR G. van
- Date : 24/08/1987
- Langues : Anglais
- Source : Development in refrigeration, refrigeration for development. Proceedings of the XVIIth international Congress of Refrigeration.
- Formats : PDF
Voir la fiche
-
Experimental investigation of the temperatures ...
- Auteurs : LÓPEZ-NAVARRO A., BIOSCA-TARONGER J., TORREGROSA-JAIME B., et al.
- Date : 06/2013
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 36 - n. 4
- Formats : PDF
Voir la fiche
-
NOUVEAUX SYSTEMES D'ECONOMIE D'ENERGIE POUR LES...
- Auteurs : GULDAGER F.
- Date : 04/1982
- Langues : Danois
- Source : Scand. Refrig. - vol. 11 - n. 2
Voir la fiche
-
Development of the CO2 refrigerated showcase.
- Auteurs : ISHIKAWA T., TASHIRO Y.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche