Etude des chutes de pression liées au frottement dans un système à compresseur rotatif-détendeur utilisant le R-134a en tant que frigorigène.

Investigation of friction losses in a vane compressor-expander system using R-134a refrigerant.

Auteurs : AZIH C., GU J. J.

Résumé

The incorporated compressor-expander mechanism is a useful method of recovering work from the expansion/throttling stage of a refrigeration cycle. This paper studies the rotary-vane compressor-expander with R-134a as the working refrigerant. To improve the mechanical efficiency of the compressor, a detailed mathematical model of the frictional forces is created. Viscous shear losses caused by the lubrication additives, vane tip frictional losses and sealing losses are mathematically modelled as functions of various fluid and geometrical parameters of the compressor-expander. Results from the model correlate well with the experimental data obtained. As such, the model can be used to achieve improvements in system efficiency. It is seen that for a certain maximum operating speed there is an optimum rotor end face clearance to use before the power loss due to viscous shear overcomes the power lost from leakage. Better internal lubrication is also observed to reduce the overall power consumption of the unit.

Documents disponibles

Format PDF

Pages : ICR07-E1-806

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Investigation of friction losses in a vane compressor-expander system using R-134a refrigerant.
  • Identifiant de la fiche : 2008-0590
  • Langues : Anglais
  • Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
  • Date d'édition : 21/08/2007

Liens


Voir d'autres communications du même compte rendu (839)
Voir le compte rendu de la conférence