Résumé
The more ecological alternatives to R-404A such is the R-448A, R-449A or R-452A are viable nonflammable fluids for low temperature refrigeration. Very low evaporation temperatures can be achieved with two-stage reciprocating compressors, which are commercially available from multiple large manufacturers. The combination of these fluids and two-stage compressions with inter-stage cooling enables low evaporation temperature down to -70°C. The ecological replacements for R-404A have many disadvantages including lower cooling capacities, very high temperature glides and high discharge temperatures. Number of studies has been presented recently but little attention has been paid to the low temperature applications outside commercial refrigeration. We present a comparison of R-448A and R-404A refrigerants to R-218, which can be taken as a benchmark fluid in our field of low temperature cooling of high-tech electronic devices like elementary particle detectors. Our measurements were performed using special oil-less experiment cooling circuit equipped with large number of pressure and temperature sensor, flowmeters, etc. We have used Roman Pot detectors as a real power load that is installed in the Large Hadron Collider tunnel at CERN.
Documents disponibles
Format PDF
Pages : 9
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Study of R-404A and R-448A refrigerants in low temperature refrigeration of electronics.
- Identifiant de la fiche : 30024875
- Langues : Anglais
- Source : 1st IIR international conference on the application of HFO refrigerants, Birmingham, September 2-5 2018.
- Date d'édition : 09/2018
- DOI : http://dx.doi.org/10.18462/iir.hfo.2018.1180
Liens
- Voir aussi : Study of R-404A and R-448A refrigerants in low temperature refrigeration of electronics.
Voir d'autres communications du même compte rendu (126)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
HFC;
Autres applications industrielles - Mots-clés : R218; Électronique; Comparaison; Basse température; Refroidissement; R448a; R404A; HFO; Experimentation
-
Study of R-404A and R-448A refrigerants in low ...
- Auteurs : DOUBEK M., VACEK V.
- Date : 09/2018
- Langues : Anglais
- Source : 1st IIR international conference on the application of HFO refrigerants, Birmingham, September 2-5 2018.
- Formats : PDF
Voir la fiche
-
Comparison of R-404A, R-448A and R-452A as drop...
- Auteurs : DOUBEK M., VACEK V.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche
-
Evaporation heat transfer of the low GWP altern...
- Auteurs : KIM C. H., KIM N. H.
- Date : 08/2021
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 128
- Formats : PDF
Voir la fiche
-
Operation parameters of a walk-in cooler after ...
- Auteurs : LOKIETEK T., WISNIK P.
- Date : 06/09/2017
- Langues : Anglais
- Source : Compressors 2017: 9th International Conference on Compressors and Coolants.
- Formats : PDF
Voir la fiche
-
CRYOGENIC COOLING TECHNIQUES FOR LOW TEMPERATUR...
- Auteurs : KERNEY P. J.
- Date : 10/08/1991
- Langues : Anglais
- Source : New challenges in refrigeration. Proceedings of the XVIIIth International Congress of Refrigeration, August 10-17, 1991, Montreal, Quebec, Canada.
- Formats : PDF
Voir la fiche