Résumé
The heating capacity and coefficient of performance (COP) will significantly decrease when the conventional air source heat pump (ASHP) system is operated under low ambient temperature conditions, with the high discharge temperature. The vapor injection technique with an internal heat exchanger (IHX) has been proposed as an effective way to acquire better performance. In this paper, the performance of a R410A two-stage air source heat pump system with the scroll compressor was studied experimentally. According to the experimental results, the heating capacity increased with the vapor injection at the fixed ambient temperature and water temperature, however the discharge temperature decreased. One interesting founding was that the discharge temperature at the ambient temperature of -6°C and -12°C increased slightly when a little refrigerant was injected into the compressor. The optimal point always occurred when the system COP was maximized with the other constant parameters. Furthermore, the peak points of each COP curve were shifted to the right if the ambient temperature was elevated. With variation of the ambient temperature, the peak points of the heat pump with vapor injection technique were compared with those of the conventional system. The results showed that the vapor injection technique could improve the heating performance and enhance the stability and reliability of the compressor. At the ambient temperature of -20°C, the system could have up to 17.01% improved COP and 13.73% decreased discharge temperature, respectively. In addition, the variation of injection ratio with intermediate pressure and expansion valve operating reliability were also investigated.
Documents disponibles
Format PDF
Pages : 10
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Performance investigation of two-stage heat pump with vapor injection using R410A as working fluid.
- Identifiant de la fiche : 30024477
- Langues : Anglais
- Source : 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Date d'édition : 09/07/2018
Liens
Voir d'autres communications du même compte rendu (252)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
Techniques des pompes à chaleur;
HFC - Mots-clés : R410A; Vapeur; Pompe à chaleur; Injection; Experimentation; COP; Chauffage; Échangeur de chaleur; Compresseur à spirale
-
Effects of intermediate pressure on the heating...
- Auteurs : ROH C. W., KIM M. S.
- Date : 12/2011
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 34 - n. 8
- Formats : PDF
Voir la fiche
-
Two-stage heat pump system with vapour-injected...
- Auteurs : WANG X., HWANG Y., RADERMACHER R.
- Date : 09/2009
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 32 - n. 6
- Formats : PDF
Voir la fiche
-
Heating performance of a VRF heat pump system i...
- Auteurs : KANG D., RYU B., JEONG J. H.
- Date : 12/2018
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 96
- Formats : PDF
Voir la fiche
-
Experimental results on a vapour injection scro...
- Auteurs : ZABET I., TÂRLEA G. M.
- Date : 2012
- Langues : Anglais
- Source : Buletinul Institutului politehnic din Iasi, Sectia Constructii de Masini - vol. 58 - n. 4
Voir la fiche
-
Heating performance comparison of R410A and its...
- Auteurs : CHEN X., YANG J., LIU C., et al.
- Date : 12/2018
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 96
- Formats : PDF
Voir la fiche