Document IIF

Étude du champ de température dans les tissus cutanés lors de la dispersion de mélanges de gaz à des températures de -35,5; -25,0;-15,0°C pour application en cryomédecine et en cryothérapie.

The study of the temperature field in the skin cover when dispersing gas mixtures to -35.5; -25.0; -15.0°C temperature level for application in cryomedicine and cryotherapy.

Numéro : pap. ID: 733

Auteurs : KONDRATENKO R., BUTORINA A., NESTEROV S.

Résumé

Experimental data have been obtained on gas jet temperature distribution in various volume points when propane/butane/R123 cooling mixture throttling to -35.5; -25.0; -15.0°C temperature level from the nozzle at 0.1; 0.5; 1.0 mm diameter. the mixture was used for medical purposes. Also the study of the temperature field on the skin cover when dispersing cooling gas mixtures to -35.5; -25.0; -15.0°C temperature level has been carried out. gas mixtures were propane-butane (40/60% mole); propane/butane/r123 (12/18/70% mole); propane/butane/R123 (28/42/30% mole) dispersed from the nozzle at 0.1; 0.5; 1.0 mm diameter from the distance of 5;50;150;200;250;300 mm. obtained data allow raising the accuracy and the effectiveness of cooling spray application, evaluating and choosing efficient convection conditions in order to cool biotissue as well as defining the limit safe cooling period of the given biotissue area (skin, mucous tunic) which ends at the moment of the tissue freezing. a laboratory bench was developed to automate the work to investigate a gas jet thermodynamic parameters. the description of cooling spray for athletes “ice wave” (pre-production models) is given. the pre-production models were made in the Vekshinski Institute. The method is suggested to use the aerosol with special gauze plasters which retain refrigerating medium after spraying. Thus the cooling effect is prolonged several times as much.

Documents disponibles

Format PDF

Pages : 7 p.

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : The study of the temperature field in the skin cover when dispersing gas mixtures to -35.5; -25.0; -15.0°C temperature level for application in cryomedicine and cryotherapy.
  • Identifiant de la fiche : 30002168
  • Langues : Anglais
  • Source : Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
  • Date d'édition : 21/08/2011

Liens


Voir d'autres communications du même compte rendu (569)
Voir le compte rendu de la conférence