Document IIF
Étude et analyse d'un refroidisseur à pompe à chaleur au CO2 avec un nouvel évaporateur bi-étagé.
Investigation and analysis of a CO2 heat pump chiller with novel two-stage evaporator.
Numéro : 0352
Auteurs : BENGSCH J., HAZARIKA M. M., HAFNER A., WIDELL K. N.
Résumé
This study was carried out to investigate the performance of a transcritical CO2 heat pump chiller that provides heating and cooling simultaneously. There are several applications where such CO2 systems are implemented, i.e., hotels, commercial kitchens, fishing vessels, etc. Depending on the type of applications, these systems can be designed to achieve the desired hot and cold fluid temperature on the secondary side. The system investigated in the present study is utilized to produce hot water (up to 90°C) and chilled water (4°C). The evaporator utilized for chilled water production is a novel two-stage evaporator. The first stage of this evaporator operates on gravity-fed mode while the second stage operates on ejector-supported mode. The secondary loop is internally connected within the plate heat exchanger. This evaporator configuration gives the possibility to achieve a higher temperature gradient on the secondary fluid side. To analyze the performance of this proposed CO2 system with the two-stage evaporator, a simulation model was developed in Modelica. Using this model, simulations were carried out to analyze the performance of the system under different operating conditions. Results show that the integration of the two-stage evaporator enhances the overall performance by over 5 % as the cooling capacity is shared equally between the two stages and the suction pressure of the compressor is elevated by utilizing the ejector.
Documents disponibles
Format PDF
Pages : 12
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Investigation and analysis of a CO2 heat pump chiller with novel two-stage evaporator.
- Identifiant de la fiche : 30031400
- Langues : Anglais
- Sujet : Technologie
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Date d'édition : 21/08/2023
- DOI : http://dx.doi.org/10.18462/iir.icr.2023.0352
Liens
Voir d'autres communications du même compte rendu (491)
Voir le compte rendu de la conférence
Indexation
-
System optimization of CO2 heat pump water heat...
- Auteurs : ZHANG F. Z., JIANG P. X., ZHU Y. H., et al.
- Date : 02/08/2014
- Langues : Anglais
- Source : 11th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2014). Proceedings. Hangzhou, China, August 31-September 2, 2014.
- Formats : PDF
Voir la fiche
-
Modeling and simulation of a transcritical CO2 ...
- Auteurs : SIAN R., WANG C. C.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche
-
Optimal discharge pressure in transcritical CO<...
- Auteurs : YE Z., WANG Y., SONG Y., YIN X., CAO F.
- Date : 10/2020
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 118
- Formats : PDF
Voir la fiche
-
A comparative study to investigate two configur...
- Auteurs : HAZARIKA M. M., HAFNER A., BENGSCH J.
- Date : 27/04/2023
- Langues : Anglais
- Source : 10th IIR Conference on Ammonia and CO2 Refrigeration Technologies.
- Formats : PDF
Voir la fiche
-
100℃ Hot Water Supplied by CO2 Trans...
- Auteurs : HUANG R., HU B., GE T. S., EIKEVIK T. M.
- Date : 13/06/2022
- Langues : Anglais
- Source : 15th IIR-Gustav Lorentzen Conference on Natural Refrigerants (GL2022). Proceedings. Trondheim, Norway, June 13-15th 2022.
- Formats : PDF
Voir la fiche