Etude expérimentale d'un réfrigérateur à tube pulsé fonctionnant avec des mélanges d'hélium et d'azote.

Experimental study on pulse tube refrigeration with helium and nitrogen mixtures.

Auteurs : GAN Z. H., CHEN G. B., THUMMES G., et al.

Type d'article : Article

Résumé

An experimental investigation on two-component multi-phase helium and nitrogen mixtures in a single-stage pulse tube refrigerator was carried out. The experimental results show that both COP and cooling power can be improved to some extent at above 70 K when the nitrogen fraction in the mixture is less than 25%. An approximate stable temperature platform at the triple point 63.15 K of nitrogen, which is independent of nitrogen's fraction, is obtained when the cooling power is below 7 W.

Détails

  • Titre original : Experimental study on pulse tube refrigeration with helium and nitrogen mixtures.
  • Identifiant de la fiche : 2002-1166
  • Langues : Anglais
  • Source : Cryogenics - vol. 40 - n. 4-5
  • Date d'édition : 04/2000

Liens


Voir d'autres articles du même numéro (5)
Voir la source