Prévision des performances thermodynamiques de réfrigérateurs à tubes pulsés utilisés avec des mélanges de fluides.

Thermodynamic performance prediction of pulse tube refrigeration with mixture fluids.

Auteurs : CHEN G., GAN Z., THUMMES G., et al.

Type d'article : Article

Résumé

A refrigeration cycle with two isentropic and two isobaric processes, referred to as the modified Brayton cycle, is introduced for predicting the thermodynamic performance of pulse tube refrigeration with a binary mixture refrigerant. The corresponding theoretical expressions of cooling power, thermodynamic efficiency and required work of a refrigeration cycle are established. Based on the prediction calculations for a number of cryogenic fluids, promising mixture pairs of working refrigerants are recommended. The computed results show that 9.5% of the COP and 6.7% of the cooling power at 80 K could be gained if a mixture pair of 10% nitrogen and 90% helium is used instead of pure helium for the pulse tube refrigeration. The minor mixture pairs which have a positive effect on pulse tube refrigeration at temperatures near 80 K, including hydrogen-helium, argon-helium and neon-helium, are also discussed.

Détails

  • Titre original : Thermodynamic performance prediction of pulse tube refrigeration with mixture fluids.
  • Identifiant de la fiche : 2002-1170
  • Langues : Anglais
  • Source : Cryogenics - vol. 40 - n. 4-5
  • Date d'édition : 04/2000

Liens


Voir d'autres articles du même numéro (5)