Document IIF
Etude expérimentale d'un refroidisseur à absorption au LiBr/H20 à air refroidi et fonctionnant au gaz.
Experimental study of an air-cooled gas-fired LiBr/H20 absorption chiller.
Auteurs : ZHANG J.
Résumé
In this paper, it proves that with changed structure of evaporator, cooler and absorber in lithium-bromide absorption chiller, air-cooled can replace water-cooled. An air-cooled gas-fired LiBr/H2O absorption chiller is specially designed and constructed. Experimental research on performance of the absorption chiller has been carried out under various operating conditions by advanced testing means. The system's performance under different environment temperature, absorption temperature and generation temperature are obtained. The different parameters having influences on the cooling capacity of the absorption chiller are also analyzed and discussed.
Documents disponibles
Format PDF
Pages : ICR07-B2-1528
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Experimental study of an air-cooled gas-fired LiBr/H20 absorption chiller.
- Identifiant de la fiche : 2008-0175
- Langues : Anglais
- Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Date d'édition : 21/08/2007
Liens
Voir d'autres communications du même compte rendu (839)
Voir le compte rendu de la conférence
Indexation
- Thèmes : Systèmes à absorption et adsorption
- Mots-clés : Échangeur à air; Système à absorption; Performance; Experimentation; COP; Eau-bromure de lithium
-
Resultados experimentales obtenidos con un prot...
- Auteurs : IZQUIERDO M., MARTIN E., GONZALEZ A., et al.
- Date : 22/02/2012
- Langues : Espagnol
- Source : CYTEF 2012. VI Congreso Ibérico y IV Congreso Iberoamericano de Ciencias y Técnicas del Frío, Madrid, España, 22-24 de febrero, 2012.
- Formats : PDF
Voir la fiche
-
Commercial absorption chiller models for evalua...
- Auteurs : KOEPPEL E. A., KLEIN S. A., MITCHELL J. W.
- Date : 01/1995
- Langues : Anglais
- Source : ASHRAE Transactions.
Voir la fiche
-
Performance of water-lithium bromide absorption...
- Auteurs : KOJIMA M., FUJITA T., IRIE T., et al.
- Date : 01/08/2004
- Langues : Anglais
- Source : Natural Working Fluids 2004: 6th IIR-Gustav Lorentzen Conference
- Formats : PDF
Voir la fiche
-
Influence of solution heat exchanger efficiency...
- Auteurs : GUTIERREZ G., RODRÍGUEZ P., RODRIGUEZ M. C., et al.
- Date : 12/04/2010
- Langues : Anglais
- Source : 9th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2010). Proceedings. Sydney, Australia, April 12-14, 2010.
- Formats : PDF
Voir la fiche
-
Analysis of the part load behaviour of sorption...
- Auteurs : ALBERS J., ZIEGLER F.
- Date : 17/08/2003
- Langues : Anglais
- Source : 21st IIR International Congress of Refrigeration: Serving the Needs of Mankind.
- Formats : PDF
Voir la fiche