Document IIF
Étude expérimentale d’un système de chauffage par pompe à chaleur à cycle à air régénéré avec turbocompresseur.
Experimental investigation of a regenerated air cycle heat pump heating system with a turbocharger.
Résumé
An air cycle heat pump test bench with a turbocharger and two blowers was designed and presented in this paper. The heating performance of this air cycle heat pump was then experimentally investigated under different operating parameters. The results showed that the pressure ratios of the compressor and turbine could be maintained within the reasonable ranges under the test conditions covered, which means that the two blowers were more suitable for this air cycle heat pump with a turbocharger than one blower. The heating capacity of this heat pump increased as the ambient temperature decreased, while the heating COP was less affected by the hot water supply temperature and the ambient temperature. This indicated that the regenerated air cycle heat pump with the turbocharger could offer more stable operation in applications with a large ambient temperature difference.
Documents disponibles
Format PDF
Pages : 48-54
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Experimental investigation of a regenerated air cycle heat pump heating system with a turbocharger.
- Identifiant de la fiche : 30025597
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 100
- Date d'édition : 04/2019
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2018.12.029
Liens
Voir d'autres articles du même numéro (46)
Voir la source
Indexation
-
Thèmes :
Techniques des pompes à chaleur;
Autres frigorigènes - Mots-clés : Banc d'essai; Régénération; Pompe à chaleur; Performance; Experimentation; Cycle à air; Chauffage
-
Banc d'essais pour une pompe à chaleur aérauliq...
- Auteurs : WANG S., ZU F., JIN X., et al.
- Date : 05/2012
- Langues : Chinois
- Source : HV & AC - vol. 42 - n. 263
- Formats : PDF
Voir la fiche
-
Performance de pompes à chaleur à vis utilisant...
- Auteurs : SANADA M., OTA N., OKAMOTO Y., OGURA M., TERASAWA H.
- Date : 08/1993
- Langues : Japonais
- Source : Refrigeration - vol. 68 - n. 790
Voir la fiche
-
Process model design for positive displacement ...
- Auteurs : VERING C., MÖNTENICH J., RÄTZ M., KLEBIG T., STREBLOW R., MÜLLER D.
- Date : 01/2024
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 157
- Formats : PDF
Voir la fiche
-
Optimising exchangers.
- Auteurs : ROBERTS L., GREEN R.
- Date : 06/1995
- Langues : Anglais
Voir la fiche
-
Une renaissance des pompes à chaleur entraînées...
- Auteurs : MEIDEL B., KELLER E., GOTTSCHALK R.
- Date : 06/1992
- Langues : Allemand
- Source : Kälte + Klimatechnik (Die) - vol. 45 - n. 6
Voir la fiche