Résumé
The radiation cooling is experimentally studied wi th air as the cooling medium. polyester (PET) as radiative material and low-density polyethylEne (LDPE) film as transparent cover. The experimental results with horizontal device indicate that the maximum temperature difference between PET and the environment is 9.9°C, and that between internal air and the environment is 7.2°C. In the same climatic condition for the device tilted, the results for 45° tilt angle are the best, the maximum temperature difference between internal air and the environment is 7.6°C. In the air flow experiment, the maximum temperature difference is obta ined at wind speed of 0.6m/s~0.8m/s, the temperature difference between the outlet and environment is 5.2°C, and the stable temperature difference is obtained throughout the night. By calculation, the effective cooling power of the device is 73.6 W/m2.
Documents disponibles
Format PDF
Pages : 48-52
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : [In Chinese. / En chinois.]
- Identifiant de la fiche : 30003125
- Langues : Chinois
- Source : Journal of Refrigeration - n. 140
- Date d'édition : 08/2011
Liens
Voir d'autres articles du même numéro (13)
Voir la source
Indexation
- Thèmes : Conditionnement d'air pour le confort
- Mots-clés : Froid radiatif; Rayonnement; Refroidissement; Polyéthylène; Polyester; Film; Experimentation
-
Free subcooling with the sky: Improving the eff...
- Auteurs : GOLDSTEIN E., NASUTA D., LI S., et al.
- Date : 09/07/2018
- Langues : Anglais
- Source : 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Experimental Study on the Performance of a Spac...
- Auteurs : ZHUANG Z., XU Y., WU Q., LIU B., LI B., ZHAO J., YANG X.
- Date : 10/2022
- Langues : Anglais
- Source : Energies - vol. 15 - n. 19
- Formats : PDF
Voir la fiche
-
Evaluation of indoor environment in office buil...
- Auteurs : DURISOVÁ E., PETRÁS D.
- Date : 12/2011
- Langues : Anglais
- Source : REHVA Journal - vol. 48 - n. 6
Voir la fiche
-
Comparison of three transient models for heatin...
- Auteurs : REY A., DUMOULIN R., ATHIENITIS A. K.
- Date : 09/07/2018
- Langues : Anglais
- Source : 2018 Purdue Conferences. 5th International High Performance Buildings Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Estudio de un sistema de climatización radiante...
- Auteurs : MOIÁ-POL A., ROSSELLÓ BATLE B., MAS GARCIA B.
- Date : 03/05/2016
- Langues : Espagnol
- Source : CYTEF 2016. VIII Congreso Ibérico y VI Congreso Iberoamericano de las Ciencias y Técnicas del Frío, Coimbra-Portugal, 3-6 mayo, 2016.
- Formats : PDF
Voir la fiche