Document IIF
Etude expérimentale de l'effet de la longueur de ma chambre de mélange sur la performance d'un éjecteur diphasique pour un cycle frigorifique au CO2 avec et sans échangeurs de chaleur.
Experimental investigation on the effect of mixing length on the performance of two-phase ejector for CO2 refrigeration cycle with and without heat exchangers.
Auteurs : NAKAGAWA M., MARASIGAN A. R., MATSUKAWA T., et al.
Résumé
In ejector systems using the promising natural refrigerant CO2, the mixing of high speed two-phase primary flow and suction vapour is crucial in designing an efficient ejector. In this study, the effect of mixing length on ejector system performance was analyzed experimentally. The mixing lengths used were 5, 15 and 25 mm, with constant rectangular cross-section. The experiments were performed for both ejector and conventional expansion systems with and without internal heat exchanger. The gas cooler pressure (9-10.5 MPa), evaporator temperature (2-8°C), and gas cooler outlet temperature (41-44°C) were varied for each type. The results showed the significant effect of mixing length in ejector's performance. The 15 mm-type provided the highest pressure recovery, entrainment ratio and COP in all the conditions used in this research. A maximum COP improvement of up to 26% compared to similar conventional system was obtained.
Documents disponibles
Format PDF
Pages : 2010-2
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Experimental investigation on the effect of mixing length on the performance of two-phase ejector for CO2 refrigeration cycle with and without heat exchangers.
- Identifiant de la fiche : 2010-1149
- Langues : Anglais
- Source : 9th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2010). Proceedings. Sydney, Australia, April 12-14, 2010.
- Date d'édition : 12/04/2010
Liens
- Voir les traductions : Investigación experimental sobre el efecto de la longitud de mezcla en el rendimiento del eyector bifásico para el ciclo de refrigeración del CO2, con y sin intercambiador de calor.
Voir d'autres communications du même compte rendu (84)
Voir le compte rendu de la conférence
-
Experimental investigation of different ejector...
- Auteurs : HAFNER A., LADAM Y., ANDRESEN T., et al.
- Date : 12/04/2010
- Langues : Anglais
- Source : 9th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2010). Proceedings. Sydney, Australia, April 12-14, 2010.
- Formats : PDF
Voir la fiche
-
Investigation of a novel CO2 ultrahi...
- Auteurs : HERDEN D., DOERFFEL C., BARTA R. B., THOMAS C.
- Date : 21/08/2023
- Langues : Anglais
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
Voir la fiche
-
Experimental investigation of an ultrahigh-lift...
- Auteurs : HERDEN D., XU Y., BARTA R. B., THOMAS C.
- Date : 08/2024
- Langues : Anglais
- Source : 16th IIR-Gustav Lorentzen Conference on Natural Refrigerants (GL2024). Proceedings. University of Maryland, College Park, Maryland, USA, August 11-14 2024
- Formats : PDF
Voir la fiche
-
Experimentelle und theoretische Untersuchung ei...
- Auteurs : TISCHENDORF C., RICHTER C., FIORENZANO R., et al.
- Date : 22/11/2007
- Langues : Allemand
- Source : DKV-Tagungsbericht 2007, Hannover.
Voir la fiche
-
Experimental investigation of an ejector for R-...
- Auteurs : DRESCHER M., HAFNER A., JAKOBSEN A., et al.
- Date : 21/08/2007
- Langues : Anglais
- Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Formats : PDF
Voir la fiche