Document IIF
Étude expérimentale de la condensation intratubulaire de R450A à faible GWP à l’aide d’un capteur de température distribué à fibre optique.
Experimental investigation of in-tube condensation of low GWP refrigerant R450A using a fiber optic distributed temperature sensor.
Auteurs : JACOB T. A., MATTY E. P., FRONK B. M.
Type d'article : Article, Article de la RIF
Résumé
Heat transfer coefficients and frictional pressure drop values are experimentally measured during condensation of R134a and its proposed low global warming potential (GWP) replacement, R450A. R450A is a non-flammable zeotropic mixture of R134a and R1234ze (42/58% by mass). Experiments were conducted in a horizontal tube (ID = 4.7 mm) for a range of mass fluxes (100 kg m s to 550 kg m s) and saturation conditions (45 °C and 55 °C). The measured pressure drop values and heat transfer coefficients were compared with established literature correlations. Good agreement indicates that existing correlations can be used for design of condensers with R450A as the working fluid. Additionally, this study evaluates the viability of using distributed fiber optic temperature sensors during refrigerant condensation experiments. The fiber sensor is installed in the annulus of a tube-in-tube heat exchanger and is used to obtain the axial temperature profile of the cooling water. The measurements from the distributed temperature sensors are compared with conventional RTD measurements co-located within the test section. The results (Average Deviation = ±0.26 °C, Maximum Deviation = ±1.11 °C) suggest that fiber optic measurement techniques can provide temperature data with accuracy and high spatial resolution (equal to 0.65 mm).
Documents disponibles
Format PDF
Pages : 274-286
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Experimental investigation of in-tube condensation of low GWP refrigerant R450A using a fiber optic distributed temperature sensor.
- Identifiant de la fiche : 30026144
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 103
- Date d'édition : 07/2019
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2019.04.021
Liens
Voir d'autres articles du même numéro (28)
Voir la source
Indexation
-
Thèmes :
HFC;
Mélanges - Mots-clés : Capteur; Faible GWP; R450A; Mélange zéotropique; Fibre optique; Experimentation; Condensation; Chute de pression
-
Experimental study of R450A drop-in performance...
- Auteurs : MAKHNATCH P., MOTA BABILONI A., KHODABANDEH R.
- Date : 12/2017
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 84
- Formats : PDF
Voir la fiche
-
Condensation characteristics of non-azeotropic ...
- Auteurs : HIROSE M., JIGE D., INOUE N.
- Date : 06/2021
- Langues : Anglais
- Source : 2nd IIR Conference on HFO Refrigerants and Low GWP Blends
- Formats : PDF
Voir la fiche
-
Condensation heat transfer and pressure drop of...
- Auteurs : JIGE D., MIKAJIRI N., KIKUCHI S., INOUE N.
- Date : 12/2020
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 120
- Formats : PDF
Voir la fiche
-
Pressure drop of low GWP refrigerant mixture of...
- Auteurs : UBUDIYAH H., MAINIL A. K., SADAKATA K., KARIYA K., MIYARA A.
- Date : 2022
- Langues : Anglais
- Source : 2022 Purdue Conferences. 19th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Two-phase heat transfer performance of ternary ...
- Auteurs : AZZOLIN M., BERTO A., BORTOLIN S., et al.
- Date : 09/2018
- Langues : Anglais
- Source : 1st IIR international conference on the application of HFO refrigerants, Birmingham, September 2-5 2018.
- Formats : PDF
Voir la fiche