Étude expérimentale de la pression optimale de rejet de chaleur pour un chauffe-eau à pompe à chaleur au CO2 transcritique.
Experimental investigation of the optimal heat rejection pressure for a transcritical CO2 heat pump water heater.
Auteurs : QI P. C., HE Y. L., WANG X. L., et al.
Type d'article : Article
Résumé
The system performance of a transcritical CO2 heat pump is significantly influenced by the heat rejection pressure due to the nature of the transcritical refrigeration cycle. It has received wide attention in the scientific community. In this article, an experimental investigation of the optimal heat rejection pressure for a transcritical CO2 heat pump water heater is presented. It is found that the optimal heat rejection pressure varies with gas-cooler outlet refrigeration temperature at different ambient temperatures. The further experimental results show that the Coefficient of Performance (COP) at the optimal heat rejection pressure decreases substantially with increasing gas-cooler outlet refrigeration temperature in a range from 25 to 45°C. Based on the experimental data, a simple correlation of the optimal heat rejection pressure in terms of gas-cooler outlet refrigeration temperature is obtained. The analysis shows that the deviation of the correlation is within ±5%, and the predicted COP at the optimal heat rejection pressure is within 6%.
Détails
- Titre original : Experimental investigation of the optimal heat rejection pressure for a transcritical CO2 heat pump water heater.
- Identifiant de la fiche : 30007648
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 56 - n. 1-2
- Date d'édition : 07/2013
- DOI : http://dx.doi.org/10.1016/j.applthermaleng.2013.03.045
Liens
Voir d'autres articles du même numéro (4)
Voir la source
Indexation
-
Thèmes :
Techniques des pompes à chaleur;
CO2 - Mots-clés : Chaleur; R744; Pompe à chaleur; Pression; Experimentation; Cycle transcritique; Chauffage; Eau; CO2
-
The experimental investigation on a novel trans...
- Auteurs : CAO F., CUI C., WEI X., et al.
- Date : 10/2019
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 106
- Formats : PDF
Voir la fiche
-
Field evaluation for air-source transcritical C...
- Auteurs : HU B., HE Y., WANG S., et al.
- Date : 14/07/2014
- Langues : Anglais
- Source : 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Difference analysis on optimal high pressure of...
- Auteurs : LIANG X. Y., HE Y. J., CHENG J. H., et al.
- Date : 10/2019
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 106
- Formats : PDF
Voir la fiche
-
Oxid uhlicitý jako chladivo Cást 3: CO2 v tepel...
- Auteurs : PETRÁK M.
- Date : 02/2016
- Langues : Tchèque
- Source : Vytápení Vetrání Instalace - vol. 25 - n. 1
- Formats : PDF
Voir la fiche
-
Multi-factor coupling optimization of heat reco...
- Auteurs : ZHENG Z., SONG Y., WANG S., YANG X., CAO F., YANG T.
- Date : 11/2024
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 167
- Formats : PDF
Voir la fiche