Etude expérimentale des caractéristiques du débit oscillant dans un régénérateur de cryoréfrigérateur à tube à pulsation.

Experimental study of the oscillating flow characteristics for a regenerator in a pulse tube cryocooler.

Auteurs : JU Y., JIANG Y., ZHOU Y.

Type d'article : Article

Résumé

A dynamic experimental apparatus was designed and constructed to investigate oscillating flow characteristics in a regenerator subjected to a periodically reversing flow established by means of a self-made linear compressor. Detailed experimental data of oscillating pressure drops and phase shift characteristics for regenerators in a high frequency pulse tube cryocooler with an operating frequency of 50 hertz were given. The correlation equations for the maximum and cycle-average friction factors in terms of Reynolds number and dimensionless distance X were obtained.

Détails

  • Titre original : Experimental study of the oscillating flow characteristics for a regenerator in a pulse tube cryocooler.
  • Identifiant de la fiche : 1999-3336
  • Langues : Anglais
  • Source : Cryogenics - vol. 38 - n. 6
  • Date d'édition : 06/1998

Liens


Voir d'autres articles du même numéro (6)
Voir la source