Document IIF
Étude expérimentale du bilan énergétique lors de l'ouverture de la porte d'un camion frigorifique.
Experimental investigation of energy balance during the door opening of a refrigerated truck.
Numéro : pap. n. 688
Auteurs : LAFAYE DE MICHEAUX T., SARTRE V., BONJOUR J.
Résumé
An experimental study on the infiltration thermal load during the door opening of a 6 m long truck body was carried out by means of energy and mass balances. The cooling capacity provided at the evaporator was measured, as well as the internal and external air temperatures and humidities. Tests were performed according to the following procedure. The inside air and the walls were settled at the set point temperature. The refrigeration unit was then stopped and the door was kept open during a 5 min period of time. The unit was then switched on again to restore the initial temperature of the air and of the walls. The global infiltration thermal load during the opening time was deduced from these measurements and analyzed against relative humidity of the ambient. Results show that the latent heat load is not negligible compared to the sensible load. It should therefore be taken into account in the energy balance of the body with an open door.
Documents disponibles
Format PDF
Pages : 8 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Experimental investigation of energy balance during the door opening of a refrigerated truck.
- Identifiant de la fiche : 30015576
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Date d'édition : 16/08/2015
- DOI : http://dx.doi.org/10.18462/iir.icr.2015.0688
Liens
Voir d'autres communications du même compte rendu (657)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
Isolation des engins de transport;
Transport routier - Mots-clés : Ouverture; Bilan thermique; Air; Porte; Experimentation; Engin réfrigérant; Fuite
-
Proposal of a method to determine the effects o...
- Auteurs : REINA A., SUQUET T., CAPO C., LATCHAN F., MAURO A. W., CAVALIER G.
- Date : 26/08/2020
- Langues : Anglais
- Source : 6th IIR International Conference on Sustainability and the Cold Chain. Proceedings: Nantes, France, August 26-28 2020
- Formats : PDF
Voir la fiche
-
Cold is gold: the effect of insulated door open...
- Auteurs : STEWART A.
- Date : 12/2001
- Langues : Anglais
- Source : S. A. Refrig. Aircond. - vol. 17 - n. 6
Voir la fiche
-
LE FROID DANS LE TRANSPORT A COURTE DISTANCE PO...
- Auteurs : BARNILS C., NAVARRO C.
- Date : 07/08/1983
- Langues : Français
- Source : [Refrigeration serving humanity]. Proceedings of the XVIth international Congress of Refrigeration.
- Formats : PDF
Voir la fiche
-
Infiltration heat load through the doorway of a...
- Auteurs : CLAVIER F., SARTRE V., BONJOUR J.
- Date : 21/08/2011
- Langues : Anglais
- Source : Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
- Formats : PDF
Voir la fiche
-
Étude expérimentale des variations de températu...
- Auteurs : LV N., XIE R., LIU G.
- Date : 04/2013
- Langues : Chinois
- Source : Journal of Refrigeration - vol. 34 - n. 2
- Formats : PDF
Voir la fiche