Document IIF
Charge thermique due à l'inflitration par la porte d'un camion frigorifique protégé par un rideau d'air.
Infiltration heat load through the doorway of a refrigerated truck protected with an air curtain.
Numéro : pap. ID: 783
Auteurs : CLAVIER F., SARTRE V., BONJOUR J.
Résumé
This paper is an experimental investigation of the heat load through the doorway of a single-compartment medium-size truck. The doorway may be unprotected or protected by two types of air curtains (ambient single, or double with one being refrigerated). Experiments were carried out in a climatic tunnel with an isothermal container for given indoor and outdoor temperatures, but with accurately measured but non controlled outdoor relative humidity. These experiments show the advantage of the double air curtain system to improve the stability of the temperature of the air during door openings, but with an increased infiltration heat load. The single curtain system is less efficient in terms of temperature stability, but it allows a reduction in the heat load.
Documents disponibles
Format PDF
Pages : 8 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Infiltration heat load through the doorway of a refrigerated truck protected with an air curtain.
- Identifiant de la fiche : 30001873
- Langues : Anglais
- Source : Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
- Date d'édition : 21/08/2011
Liens
Voir d'autres communications du même compte rendu (569)
Voir le compte rendu de la conférence
Indexation
-
Experimental investigation of energy balance du...
- Auteurs : LAFAYE DE MICHEAUX T., SARTRE V., BONJOUR J.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche
-
Proposal of a method to determine the effects o...
- Auteurs : REINA A., SUQUET T., CAPO C., LATCHAN F., MAURO A. W., CAVALIER G.
- Date : 26/08/2020
- Langues : Anglais
- Source : 6th IIR International Conference on Sustainability and the Cold Chain. Proceedings: Nantes, France, August 26-28 2020
- Formats : PDF
Voir la fiche
-
Ageing of in-service refrigerated transport veh...
- Auteurs : CAPO C., PETIT J. M., REVELLIN R., BONJOUR J., CAVALIER G.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche
-
Effect of structural factors on aging curve of ...
- Auteurs : CORAIN L., MATTIELLO F., PANOZZO G., et al.
- Date : 21/08/2011
- Langues : Anglais
- Source : Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
- Formats : PDF
Voir la fiche
-
Experimental evaluation of optical absorption c...
- Auteurs : PANOZZO G., DRAGANO A., ROSSI S., et al.
- Date : 29/03/2010
- Langues : Anglais
- Source : 1st IIR International Conference on Sustainability and the Cold Chain
- Formats : PDF
Voir la fiche